    Adaptive X-ray Computed Tomography

    • CSV
    • RefMan
    • EndNote
    • BibTex
    • RefWorks
    Thumbnail
    Name:
    azu_etd_11465_sip1_m.pdf
    Size:
    8.299Mb
    Format:
    PDF
    Download
    Author
    Moore, Jared William
    Issue Date
    2011
    Keywords
    Adaptive Systems
    Computed Tomography
    Medical Imaging
    Advisor
    Barrett, Harrison H.
    Furenlid, Lars R.
    
    Metadata
    Show full item record
    Publisher
    The University of Arizona.
    Rights
    Copyright © is held by the author. Digital access to this material is made possible by the University Libraries, University of Arizona. Further transmission, reproduction or presentation (such as public display or performance) of protected items is prohibited except with permission of the author.
    Abstract
    An adaptive pre-clinical x-ray computed tomography system, named "FaCT" was designed, built, and tested at the University of Arizona's Center for Gamma-Ray Imaging (CGRI). The FaCT system possesses the unique ability to change its magnification and dynamically mask the x-ray beam profile. Using these two abilities, the FaCT system can adapt its configuration to the object being imaged, and the task being performed, while achieving a reduction in the radiation dose applied for imaging.Development of the system included the design of all mechanical components, motion systems, and safety systems. It also included system integration of all electronics, motors, and communication channels. Control software was developed for the system and several high-performance reconstruction algorithms were implemented on graphics processing units for reconstructing tomographic data sets acquired by the system. A new geometrical calibration method was developed for calibrating the system that makes use of the full image data gathered by the system and does not rely on markers.An adaptive imaging procedure consisting of a preliminary scout scan, human guidance, and a diagnostic quality scan was developed for imaging small volumes of interest in the interior of an object at substantially reduced dose. The adaptive imaging procedure makes use of FaCT's adjustable magnification, beam-masking capability, and high-performance reconstruction software to achieve high-quality reconstruction of a volume of interest with less dose than would be required by a traditional x-ray computed tomography system without adaptive capabilities.To address ongoing research into mathematical rules for adapting an imaging system, such as FaCT, to better perform a given estimation task, a method of quantifying a system's ability to estimate a parameter of interest in the presence of nuisance parameters based on the Fisher Information was proposed. The method requires a statistical model of object variability. Possible strategies for increasing the performance of an estimation task, given an adaptive system, were suggested.
    Type
    Electronic Dissertation
    text
    Degree Name
    Ph.D.
    Degree Level
    doctoral
    Degree Program
    Graduate College
    Optical Sciences
    Degree Grantor
    University of Arizona
    Collections
    Dissertations

    entitlement

     
    The University of Arizona Libraries | 1510 E. University Blvd. | Tucson, AZ 85721-0055
    Tel 520-621-6442 | repository@u.library.arizona.edu
    DSpace software copyright © 2002-2017  DuraSpace
    Quick Guide | Contact Us | Send Feedback
    Open Repository is a service operated by 
    Atmire NV
     

    Export search results

    The export option will allow you to export the current search results of the entered query to a file. Different formats are available for download. To export the items, click on the button corresponding with the preferred download format.

    By default, clicking on the export buttons will result in a download of the allowed maximum amount of items.

    To select a subset of the search results, click "Selective Export" button and make a selection of the items you want to export. The amount of items that can be exported at once is similarly restricted as the full export.

    After making a selection, click one of the export format buttons. The amount of items that will be exported is indicated in the bubble next to export format.