Starting high inertia, high friction loads from limited power sources.
Name:
azu_td_8822426_sip1_m.pdf
Size:
2.539Mb
Format:
PDF
Description:
azu_td_8822426_sip1_m.pdf
Author
Kheder, Abdul-Sameei Yaseen.Issue Date
1988Advisor
Russell, PaulMattson, Roy H.
Metadata
Show full item recordPublisher
The University of Arizona.Rights
Copyright © is held by the author. Digital access to this material is made possible by the University Libraries, University of Arizona. Further transmission, reproduction or presentation (such as public display or performance) of protected items is prohibited except with permission of the author.Abstract
At starting, electrical motors require large power and current. This may not be a problem in a large electrical system but it may be very severe for a limited power source like a solar array. If a direct approach is taken the array rating must be 5-6 times the motor rating in order to start the motor and its high inertia high friction load. Batteries have been used to store energy and supply that energy for starting. Batteries need maintenance and their low efficiency is a problem too. In this study a new type of controller has been suggested and developed for the use with D.C. motors. Computer simulation showed promising results. The controller uses the array power, which is equal to the rated power of the motor, for starting and for running condition. Experimental results showed that the theoretical results are applicable.Type
textDissertation-Reproduction (electronic)
Degree Name
Ph.D.Degree Level
doctoralDegree Program
Electrical and Computer EngineeringGraduate College