Show simple item record

dc.contributor.advisorBarnett, H.H.en_US
dc.contributor.authorRowe, Robert Kjell.
dc.creatorRowe, Robert Kjell.en_US
dc.date.accessioned2011-10-31T17:36:52Z
dc.date.available2011-10-31T17:36:52Z
dc.date.issued1991en_US
dc.identifier.urihttp://hdl.handle.net/10150/185409
dc.description.abstractThis dissertation presents the results of an investigation into the performance characteristics of a unique hemispherical SPECT (single-photon emission computed tomography) imaging system capable of producing three-dimensional (3D) tomographic images of the human brain. The system is completely stationary and collects all necessary views of the patient simultaneously, with no system motion. The imager consists of twenty small (10cm x 10cm crystal area), digital gamma cameras arranged in a hemispherical pattern around the patient's head and a hemispherical lead aperture. The hemispherical aperture is positioned between the cameras and the head and contains a large number of pinholes; in this way each camera sees a number of overlapping pinhole projections of the radioactive distribution within the patient's brain. The initial investigation of the performance characteristics of a 3D SPECT system of this design were carried out using a computer simulation in which effects due to radiometry, finite pinhole size, finite detector resolution, photon noise, and object attenuation were included. We used a digital 3D brain phantom as the test object and an iterative search algorithm to perform the reconstructions. The simulations were used to compare the performance of a variety of system configurations. Based upon the results of the simulation study, we constructed a laboratory prototype of the 3D SPECT system, which we used to further characterize the expected performance of a clinical imaging system of the same design. Prior to collecting SPECT data we calibrated the imaging system, which required that we efficiently measure and store the spatially variant system response function. These calibration data were then included in the reconstructions of the SPECT phantoms that we imaged. A number of different SPECT phantoms were imaged to demonstrate the system performance. We measured a reconstructed spatial resolution of 4.8mm full-width at half-maximum and a full-system sensitivity of 36cps/μCi, where both values were measured for a point source in air located at the center of the field of view. We also describe an analysis that we performed to determine the equivalent, non-multiplexed system sensitivity; using this method, we found that the equivalent sensitivity was 79% of the measured value for the system configuration and the particular task that we investigated.
dc.language.isoenen_US
dc.publisherThe University of Arizona.en_US
dc.rightsCopyright © is held by the author. Digital access to this material is made possible by the University Libraries, University of Arizona. Further transmission, reproduction or presentation (such as public display or performance) of protected items is prohibited except with permission of the author.en_US
dc.subjectDissertations, Academicen_US
dc.subjectSingle-photon emission computed tomographyen_US
dc.subjectThree-dimensional imaging.en_US
dc.titleA system for three-dimensional SPECT without motion.en_US
dc.typetexten_US
dc.typeDissertation-Reproduction (electronic)en_US
dc.identifier.oclc709777061en_US
thesis.degree.grantorUniversity of Arizonaen_US
thesis.degree.leveldoctoralen_US
dc.contributor.committeememberShoemaker, R.L.
dc.identifier.proquest9123462en_US
thesis.degree.disciplineOptical Sciencesen_US
thesis.degree.disciplineGraduate Collegeen_US
thesis.degree.namePh.D.en_US
dc.description.noteThis item was digitized from a paper original and/or a microfilm copy. If you need higher-resolution images for any content in this item, please contact us at repository@u.library.arizona.edu.
dc.description.admin-noteOriginal file replaced with corrected file August 2023.
refterms.dateFOA2018-09-03T08:58:55Z
html.description.abstractThis dissertation presents the results of an investigation into the performance characteristics of a unique hemispherical SPECT (single-photon emission computed tomography) imaging system capable of producing three-dimensional (3D) tomographic images of the human brain. The system is completely stationary and collects all necessary views of the patient simultaneously, with no system motion. The imager consists of twenty small (10cm x 10cm crystal area), digital gamma cameras arranged in a hemispherical pattern around the patient's head and a hemispherical lead aperture. The hemispherical aperture is positioned between the cameras and the head and contains a large number of pinholes; in this way each camera sees a number of overlapping pinhole projections of the radioactive distribution within the patient's brain. The initial investigation of the performance characteristics of a 3D SPECT system of this design were carried out using a computer simulation in which effects due to radiometry, finite pinhole size, finite detector resolution, photon noise, and object attenuation were included. We used a digital 3D brain phantom as the test object and an iterative search algorithm to perform the reconstructions. The simulations were used to compare the performance of a variety of system configurations. Based upon the results of the simulation study, we constructed a laboratory prototype of the 3D SPECT system, which we used to further characterize the expected performance of a clinical imaging system of the same design. Prior to collecting SPECT data we calibrated the imaging system, which required that we efficiently measure and store the spatially variant system response function. These calibration data were then included in the reconstructions of the SPECT phantoms that we imaged. A number of different SPECT phantoms were imaged to demonstrate the system performance. We measured a reconstructed spatial resolution of 4.8mm full-width at half-maximum and a full-system sensitivity of 36cps/μCi, where both values were measured for a point source in air located at the center of the field of view. We also describe an analysis that we performed to determine the equivalent, non-multiplexed system sensitivity; using this method, we found that the equivalent sensitivity was 79% of the measured value for the system configuration and the particular task that we investigated.


Files in this item

Thumbnail
Name:
azu_td_9123462_sip1_c.pdf
Size:
9.819Mb
Format:
PDF

This item appears in the following Collection(s)

Show simple item record