Show simple item record

dc.contributor.authorHenker, Richard
dc.creatorHenker, Richarden_US
dc.date.accessioned2013-03-28T10:05:41Zen
dc.date.available2013-03-28T10:05:41Zen
dc.date.issued1987en_US
dc.identifier.urihttp://hdl.handle.net/10150/276466en
dc.description.abstractThe aim of the research was to investigate the effects of three parameters of the artificial heart on the (+) dP/dt max. The study was conducted using a mock circulation which was connected to an artificial heart. The data were collected using the COMDU software developed for the computer which monitors the artificial heart. Stepwise regression analysis was utilized to test the three hypotheses. Two of the null hypotheses for the study could not be rejected, as the independent variable did not significantly affect (+) dP/dt max. Although the third hypothesis was accepted, the results were not clinically significant. Limitations in the study were multicollinearity among the independent variables, small sample size, and the inability of the mock circulation to represent human responses.
dc.language.isoen_USen_US
dc.publisherThe University of Arizona.en_US
dc.rightsCopyright © is held by the author. Digital access to this material is made possible by the University Libraries, University of Arizona. Further transmission, reproduction or presentation (such as public display or performance) of protected items is prohibited except with permission of the author.en_US
dc.subjectHeart, Artificial.en_US
dc.subjectBlood pressure -- Regulation.en_US
dc.titlePNEUMATIC ARTIFICIAL HEART DRIVER PARAMETER EFFECTS ON THE RATE OF PRESSURE CHANGE ((+) DP/DT MAX)en_US
dc.typetexten_US
dc.typeThesis-Reproduction (electronic)en_US
dc.identifier.oclc17939101en_US
thesis.degree.grantorUniversity of Arizonaen_US
thesis.degree.levelmastersen_US
dc.identifier.proquest1331408en_US
thesis.degree.disciplineGraduate Collegeen_US
thesis.degree.disciplineNursingen_US
thesis.degree.nameM.S.en_US
dc.identifier.bibrecord.b1642427xen_US
refterms.dateFOA2018-06-23T15:38:23Z
html.description.abstractThe aim of the research was to investigate the effects of three parameters of the artificial heart on the (+) dP/dt max. The study was conducted using a mock circulation which was connected to an artificial heart. The data were collected using the COMDU software developed for the computer which monitors the artificial heart. Stepwise regression analysis was utilized to test the three hypotheses. Two of the null hypotheses for the study could not be rejected, as the independent variable did not significantly affect (+) dP/dt max. Although the third hypothesis was accepted, the results were not clinically significant. Limitations in the study were multicollinearity among the independent variables, small sample size, and the inability of the mock circulation to represent human responses.