Show simple item record

dc.contributor.advisorCrutchfield, Clifton D.en_US
dc.contributor.authorHazuka, John Anthony, 1964-
dc.creatorHazuka, John Anthony, 1964-en_US
dc.date.accessioned2013-03-28T10:16:32Zen
dc.date.available2013-03-28T10:16:32Zen
dc.date.issued1988en_US
dc.identifier.urihttp://hdl.handle.net/10150/276766en
dc.description.abstractProblems associated with instruments used to measure low levels of NO₂ include non-specificity, low sensitivity, and an uncharacterized dependence on environmental conditions. MDA Scientific has recently introduced a continuous colorimetric tape technique (chemcassette) to monitor for pollutant gases. Advantages of this technology include ease of use, fast-response alarm capability, and adaptability to measure different pollutants. This research characterized and compared chemcassette performance for NO₂ with other low-level NO₂ monitoring technologies including the luminox LMA-3 monitor and the EPA reference CSI chemiluminescnt monitor. The test protocol was based on EPA procedures. The chemcassette was found to be sensitive to temperature and relative humidity effects. The chemiluminescent monitor had the best overall performance. The luminox monitor displayed temperature dependence. Variation in stability of the chemcassette optical system, tape paper uniformity, and possible interference from ozone were characterized. (Abstract shortened with permission of author.)
dc.language.isoen_USen_US
dc.publisherThe University of Arizona.en_US
dc.rightsCopyright © is held by the author. Digital access to this material is made possible by the University Libraries, University of Arizona. Further transmission, reproduction or presentation (such as public display or performance) of protected items is prohibited except with permission of the author.en_US
dc.subjectNitrogen dioxide -- Measurement.en_US
dc.subjectIndoor air pollution -- Measurement.en_US
dc.subjectColorimetric analysis.en_US
dc.titleEvaluation of chemcassette technology for monitoring low-levels of nitrogen-dioxideen_US
dc.typetexten_US
dc.typeThesis-Reproduction (electronic)en_US
dc.identifier.oclc21355806en_US
thesis.degree.grantorUniversity of Arizonaen_US
thesis.degree.levelmastersen_US
dc.identifier.proquest1334297en_US
thesis.degree.disciplineGraduate Collegeen_US
thesis.degree.disciplinePharmacology & Toxicologyen_US
thesis.degree.nameM.S.en_US
dc.identifier.bibrecord.b1722780xen_US
refterms.dateFOA2018-08-19T23:44:02Z
html.description.abstractProblems associated with instruments used to measure low levels of NO₂ include non-specificity, low sensitivity, and an uncharacterized dependence on environmental conditions. MDA Scientific has recently introduced a continuous colorimetric tape technique (chemcassette) to monitor for pollutant gases. Advantages of this technology include ease of use, fast-response alarm capability, and adaptability to measure different pollutants. This research characterized and compared chemcassette performance for NO₂ with other low-level NO₂ monitoring technologies including the luminox LMA-3 monitor and the EPA reference CSI chemiluminescnt monitor. The test protocol was based on EPA procedures. The chemcassette was found to be sensitive to temperature and relative humidity effects. The chemiluminescent monitor had the best overall performance. The luminox monitor displayed temperature dependence. Variation in stability of the chemcassette optical system, tape paper uniformity, and possible interference from ozone were characterized. (Abstract shortened with permission of author.)