dc.description.abstract | A dose rate measurement survey was performed at various locations inside the radiation chamber of the Cobalt-60 gamma irradiation facility located in Room 130, Building 20 at the University of Arizona. TLDs were used for the dose rate measurements. It was observed that the dose rates decrease rapidly with increasing distance from the source. Also, dose rates decreased with increased distance away from the centerline of the radiation chamber which is indicative of the position of the effective center of the source. Percent dose rates with respect to the dose rate of the calibration position were tabulated. | |
dc.language.iso | en_US | en_US |
dc.publisher | The University of Arizona. | en_US |
dc.rights | Copyright © is held by the author. Digital access to this material is made possible by the University Libraries, University of Arizona. Further transmission, reproduction or presentation (such as public display or performance) of protected items is prohibited except with permission of the author. | en_US |
dc.subject | Engineering, Nuclear. | en_US |
dc.subject | Physics, Elementary Particles and High Energy. | en_US |
dc.title | Dose rate measurements in the cobalt-60 gamma irradiation facility using thermoluminescent dosimeters | en_US |
dc.type | text | en_US |
dc.type | Thesis-Reproduction (electronic) | en_US |
thesis.degree.grantor | University of Arizona | en_US |
thesis.degree.level | masters | en_US |
dc.identifier.proquest | 1345380 | en_US |
thesis.degree.discipline | Graduate College | en_US |
thesis.degree.discipline | Nuclear and Energy Engineering | en_US |
thesis.degree.name | M.S. | en_US |
dc.identifier.bibrecord | .b27003280 | en_US |
refterms.dateFOA | 2018-06-26T05:07:26Z | |
html.description.abstract | A dose rate measurement survey was performed at various locations inside the radiation chamber of the Cobalt-60 gamma irradiation facility located in Room 130, Building 20 at the University of Arizona. TLDs were used for the dose rate measurements. It was observed that the dose rates decrease rapidly with increasing distance from the source. Also, dose rates decreased with increased distance away from the centerline of the radiation chamber which is indicative of the position of the effective center of the source. Percent dose rates with respect to the dose rate of the calibration position were tabulated. |