dc.description.abstractThis dissertation presents the research performed to develop an optical model, improve some design parameters, and analyze the performance of the UA modular gamma camera. Initially we provide a brief background on nuclear medical imaging with scintillation cameras. The key hardware components of a camera are introduced, and some of the fundamental physics involved in the detection of gamma rays is explained. Then we describe a stand-alone modular camera imaging system that was developed to image human breasts in the clinic. The hardware and software components, calibration procedure, and general operation of the system are detailed. We explain the concepts of position estimation and scatter rejection and note how they have been applied to imaging with the UA modular gamma camera. Position estimation uses the output signals of the camera to determine where an incident gamma ray interacted within the camera, and scatter rejection uses the signals to decide whether or not an incident gamma ray underwent scattering prior to being detected by the camera. Then we present an analytical optical model of the UA modular gamma camera. Taking into account physical and optical properties of the camera components, the model performs radiometric calculations to estimate the mean response of the camera to a scintillation event anywhere within the scintillation crystal. The results of several studies using the optical model to test and improve some camera design parameters are reported. Finally, we demonstrate how straightforward signal detection theory can be used to evaluate the performance of a modular gamma camera for the task of detecting signals in noisy backgrounds. Guided by the preliminary design of a dedicated breast imaging system, estimates of how well the UA modular gamma camera can detect lesions within human breasts were generated.
dc.language.isoen_USen_US
dc.publisherThe University of Arizona.en_US
dc.rightsCopyright © is held by the author. Digital access to this material is made possible by the University Libraries, University of Arizona. Further transmission, reproduction or presentation (such as public display or performance) of protected items is prohibited except with permission of the author.en_US
dc.subjectEngineering, Biomedical.en_US
dc.subjectHealth Sciences, Radiology.en_US
dc.subjectPhysics, Optics.en_US
dc.subjectHealth Sciences, Oncology.en_US
dc.titleOptical modeling, design optimization, and performance analysis of a gamma camera for detection of breast canceren_US
dc.typetexten_US
dc.typeDissertation-Reproduction (electronic)en_US
thesis.degree.grantorUniversity of Arizonaen_US
thesis.degree.leveldoctoralen_US
dc.identifier.proquest3031385en_US
thesis.degree.disciplineGraduate Collegeen_US
thesis.degree.disciplineOptical Sciencesen_US
thesis.degree.namePh.D.en_US
dc.identifier.bibrecord.b42286542en_US
refterms.dateFOA2018-09-04T07:12:31Z
html.description.abstractThis dissertation presents the research performed to develop an optical model, improve some design parameters, and analyze the performance of the UA modular gamma camera. Initially we provide a brief background on nuclear medical imaging with scintillation cameras. The key hardware components of a camera are introduced, and some of the fundamental physics involved in the detection of gamma rays is explained. Then we describe a stand-alone modular camera imaging system that was developed to image human breasts in the clinic. The hardware and software components, calibration procedure, and general operation of the system are detailed. We explain the concepts of position estimation and scatter rejection and note how they have been applied to imaging with the UA modular gamma camera. Position estimation uses the output signals of the camera to determine where an incident gamma ray interacted within the camera, and scatter rejection uses the signals to decide whether or not an incident gamma ray underwent scattering prior to being detected by the camera. Then we present an analytical optical model of the UA modular gamma camera. Taking into account physical and optical properties of the camera components, the model performs radiometric calculations to estimate the mean response of the camera to a scintillation event anywhere within the scintillation crystal. The results of several studies using the optical model to test and improve some camera design parameters are reported. Finally, we demonstrate how straightforward signal detection theory can be used to evaluate the performance of a modular gamma camera for the task of detecting signals in noisy backgrounds. Guided by the preliminary design of a dedicated breast imaging system, estimates of how well the UA modular gamma camera can detect lesions within human breasts were generated.


Files in this item

Thumbnail
Name:
azu_td_3031385_sip1_m.pdf
Size:
9.518Mb
Format:
PDF

This item appears in the following Collection(s)

Show simple item record