    High precision and spatial analysis of platinum, palladium, and rhodium in catalytic converters by inductively coupled plasma atomic emission spectroscopy and inductively coupled plasma mass spectrometry

    • CSV
    • RefMan
    • EndNote
    • BibTex
    • RefWorks
    Thumbnail
    Name:
    azu_td_9912094_sip1_m.pdf
    Size:
    3.306Mb
    Format:
    PDF
    Download
    Author
    Pennebaker, Frank Martin, 1970-
    Issue Date
    1998
    Keywords
    Chemistry, Analytical.
    Engineering, Automotive.
    Advisor
    Denton, M. Bonner
    
    Metadata
    Show full item record
    Publisher
    The University of Arizona.
    Rights
    Copyright © is held by the author. Digital access to this material is made possible by the University Libraries, University of Arizona. Further transmission, reproduction or presentation (such as public display or performance) of protected items is prohibited except with permission of the author.
    Abstract
    The accuracy and precision of catalytic converter analysis using conventional analytical methodology such as fire assay, x-ray fluorescence, atomic absorption and ICP-AES are typically in the range of ±7-10% RSD. Due to the high cost of noble metals, methods of analysis with increased accuracy and precision are desired to evaluate the loading of noble metals onto converter bricks. The investigations described in this work have resulted in a better understanding of many of the inherent problems and have contributed new approaches for sample dissolution and analysis using array detector based Inductively Coupled Plasma Atomic Emission Spectroscopy (ICP-AES) and Inductively Coupled Plasma Mass Spectrometry (ICP-MS). These methods are shown to be accurate and precise for the analysis of Pt, Pd, and Rh in catalytic converters. Catalytic converters are difficult to dissolve by conventional acid methodology. While carius, tubes have previously been employed to dissolve small weights of sample, complete dissolution of increased amounts of sample, as needed for high precision ICP-AES analysis, has been hindered by the insufficient oxidation potential of the acids in the carius tube. In this work, the addition of ferric chloride is shown to increase the dissolving power of the carius tube method and specifically targets Pt, Pd and Rh for dissolution. Simultaneous collection of analyte wavelengths and simultaneous background correction, as performed with multichannel array detector ICP-AES instrumentation, have enhanced sensitivity and precision in catalytic converter analysis when compared to single channel instrumentation. The studies described within this dissertation demonstrate that flicker noise has been effectively eliminated through the use of multichannel array based ICP-AES instrumentation. With proper line selection and the use of the high-resolution system, Pt, Pd and Rh in catalytic converters can be analyzed with precision of 1-1.5%. ICP-AES accuracy has been confirmed through isotope dilution ICP-MS employing new methodology to avoid Zr isobaric interferences.
    Type
    text
    Dissertation-Reproduction (electronic)
    Degree Name
    Ph.D.
    Degree Level
    doctoral
    Degree Program
    Graduate College
    Chemistry
    Degree Grantor
    University of Arizona
    Collections
    Dissertations

    entitlement

     
    The University of Arizona Libraries | 1510 E. University Blvd. | Tucson, AZ 85721-0055
    Tel 520-621-6442 | repository@u.library.arizona.edu
    DSpace software copyright © 2002-2017  DuraSpace
    Quick Guide | Contact Us | Send Feedback
    Open Repository is a service operated by 
    Atmire NV
     

    Export search results

    The export option will allow you to export the current search results of the entered query to a file. Different formats are available for download. To export the items, click on the button corresponding with the preferred download format.

    By default, clicking on the export buttons will result in a download of the allowed maximum amount of items.

    To select a subset of the search results, click "Selective Export" button and make a selection of the items you want to export. The amount of items that can be exported at once is similarly restricted as the full export.

    After making a selection, click one of the export format buttons. The amount of items that will be exported is indicated in the bubble next to export format.