Show simple item record

dc.contributor.advisorYoon, Jeong Y.en_US
dc.contributor.authorFronczek, Christopher F.
dc.creatorFronczek, Christopher F.en_US
dc.date.accessioned2014-01-16T23:33:50Z
dc.date.available2014-01-16T23:33:50Z
dc.date.issued2013
dc.identifier.urihttp://hdl.handle.net/10150/311459
dc.description.abstractIn the United States and other developed countries, despite great efforts in time and funding for the prevention of foodborne and airborne diseases, there is still an unacceptable level of common pathogens spread via food, water, and air. To this end, lab-on-a-chip (LOC) technologies were developed for field-deployable assays and point of care diagnostics. These devices have potential applications in hospitals, agricultural farms, processing plants, and even on fields of battle. Two successful types of assays in the recent years towards point of care diagnostics are immunoassays and nucleic acid detection assays. In the Appendix A, we demonstrated a complete, field-deployable particle immunoassay encased within a microfluidic chip that detects small quantities of Salmonella Typhimurium in poultry fluid samples. Because the necessary reagents are pre-loaded and the test and negative control channels are fed by a single sample inlet, single pipetting of sample is possible. This assay demonstrated a 10 CFU/mL limit of detection, which is considerably lower than PCR and enzyme-linked immunosorbent assay (ELISA). Total assay time, including sample reading in an integrated handheld device, was 10 minutes, which was much lower than conventional methods. Because of the simplified protocol and assay time, this biosensor has potential in clinical and field diagnostic applications. In Appendix B, we fit the particle immunoassay to test for Influenza A H1N1/2009 virus and included aerosol sampling from a scaled-down mock classroom. To make the assay field deployable, we used an iPhone for signal detection. The detection limit of the assay was 1 pg/mL (10 pg/mL using the iPhone), which is well below the limit of detection for RT-PCR. This protocol demonstrated that immunoassays can be effective in the presence of interfering dust particles and that viruses can be collected from aerosol with minimal sample preparation. In Appendix C, we demonstrated that paper microfluidics, a newer vision of microfluidics, is a cheap and easy method to extract nucleic acid from S. Typhimurium in a variety of samples, including poultry packaging liquid, whole blood, and feces. Fluorescent detection with an iPhone allows for field and clinical testing. This protocol interfaces with rapid PCR and is a true diagnostic tool.
dc.language.isoen_USen_US
dc.publisherThe University of Arizona.en_US
dc.rightsCopyright © is held by the author. Digital access to this material is made possible by the University Libraries, University of Arizona. Further transmission, reproduction or presentation (such as public display or performance) of protected items is prohibited except with permission of the author.en_US
dc.subjectInfluenza A H1N1/2009en_US
dc.subjectMicrofluidicsen_US
dc.subjectPaper Microfluidicsen_US
dc.subjectParticle Immunoassayen_US
dc.subjectSalmonella Typhimuriumen_US
dc.subjectBiomedical Engineeringen_US
dc.subjectBiosensorsen_US
dc.titleLab-on-a-Chip Biosensors for the Rapid Detection of Pathogens in Clinical and Field Samplesen_US
dc.typetexten_US
dc.typeElectronic Dissertationen_US
thesis.degree.grantorUniversity of Arizonaen_US
thesis.degree.leveldoctoralen_US
dc.contributor.committeememberYoon, Jeong Y.en_US
dc.contributor.committeememberMatsunaga, Terry O.en_US
dc.contributor.committeememberRavishankar, Sadhanaen_US
dc.contributor.committeememberCuello, Jeol L.en_US
thesis.degree.disciplineGraduate Collegeen_US
thesis.degree.disciplineBiomedical Engineeringen_US
thesis.degree.namePh.D.en_US
refterms.dateFOA2018-06-14T10:46:26Z
html.description.abstractIn the United States and other developed countries, despite great efforts in time and funding for the prevention of foodborne and airborne diseases, there is still an unacceptable level of common pathogens spread via food, water, and air. To this end, lab-on-a-chip (LOC) technologies were developed for field-deployable assays and point of care diagnostics. These devices have potential applications in hospitals, agricultural farms, processing plants, and even on fields of battle. Two successful types of assays in the recent years towards point of care diagnostics are immunoassays and nucleic acid detection assays. In the Appendix A, we demonstrated a complete, field-deployable particle immunoassay encased within a microfluidic chip that detects small quantities of Salmonella Typhimurium in poultry fluid samples. Because the necessary reagents are pre-loaded and the test and negative control channels are fed by a single sample inlet, single pipetting of sample is possible. This assay demonstrated a 10 CFU/mL limit of detection, which is considerably lower than PCR and enzyme-linked immunosorbent assay (ELISA). Total assay time, including sample reading in an integrated handheld device, was 10 minutes, which was much lower than conventional methods. Because of the simplified protocol and assay time, this biosensor has potential in clinical and field diagnostic applications. In Appendix B, we fit the particle immunoassay to test for Influenza A H1N1/2009 virus and included aerosol sampling from a scaled-down mock classroom. To make the assay field deployable, we used an iPhone for signal detection. The detection limit of the assay was 1 pg/mL (10 pg/mL using the iPhone), which is well below the limit of detection for RT-PCR. This protocol demonstrated that immunoassays can be effective in the presence of interfering dust particles and that viruses can be collected from aerosol with minimal sample preparation. In Appendix C, we demonstrated that paper microfluidics, a newer vision of microfluidics, is a cheap and easy method to extract nucleic acid from S. Typhimurium in a variety of samples, including poultry packaging liquid, whole blood, and feces. Fluorescent detection with an iPhone allows for field and clinical testing. This protocol interfaces with rapid PCR and is a true diagnostic tool.


Files in this item

Thumbnail
Name:
azu_etd_13075_sip1_m.pdf
Size:
2.226Mb
Format:
PDF

This item appears in the following Collection(s)

Show simple item record