dc.description.abstractBackground and Significance: The i‐STAT point of care blood analyzer is a handheld device used for a variety of laboratory analyses in medical settings. Much research has been performed to evaluate its validity, but it has not been exhaustively tested in real‐world emergency department settings, despite its increasingly popular use in such settings. Methods: We retrospectively examined medical records at the Maricopa Integrated Health Systems Emergency Department to find 100 instances between February 2014 and September 2014 in which a patient had electrolyte testing performed on both the i‐STAT and in the central laboratory within a 60 minute timeframe. These data were examined using variance of means and Bland‐Altman graphing for equivalency. Results: We set the clinical equivalence threshold for each lab to be 5% of the mean normal value. That is, if the i‐STAT differed from central lab by less than 5% of the middle of the normal range (137‐145 for sodium, 5% of which is 7) then we consider them to be clinically equivalent. At this level we were unable to show clinical equivalence. In additional, all electrolytes tested showed small but significant bias between the i‐STAT and the central laboratory. Re‐examination of the data excluding all measurements more than 15 minutes apart showed similar findings. Conclusions: At this time we cannot show equivalency between the i‐STAT device and the central laboratory when used under real‐life emergency department conditions. More research is needed is to support or refute these findings.
dc.language.isoen_USen
dc.publisherThe University of Arizona.en_US
dc.rightsCopyright © is held by the author. Digital access to this material is made possible by the College of Medicine - Phoenix, University of Arizona. Further transmission, reproduction or presentation (such as public display or performance) of protected items is prohibited except with permission of the author.en_US
dc.subjectI-Staten
dc.subjectBlood Analyzeren
dc.subjectEmergency Departmenten
dc.subject.meshEmergency Service, Hospitalen
dc.subject.meshLaboratoriesen
dc.titleINTERCHANGEABILITY OF THE I‐STAT POINT OF CARE ANALYZER WITH CENTRAL LABORATORY TESTING IN AN EMERGENCY DEPARTMENT SETTINGen_US
dc.typetext; Electronic Thesisen
dc.contributor.departmentThe University of Arizona College of Medicine - Phoenixen
dc.description.collectioninformationThis item is part of the College of Medicine - Phoenix Scholarly Projects 2015 collection. For more information, contact the Phoenix Biomedical Campus Library at pbc-library@email.arizona.edu.en_US
dc.contributor.mentorSarko, Johnen
refterms.dateFOA2018-08-14T12:48:04Z
html.description.abstractBackground and Significance: The i‐STAT point of care blood analyzer is a handheld device used for a variety of laboratory analyses in medical settings. Much research has been performed to evaluate its validity, but it has not been exhaustively tested in real‐world emergency department settings, despite its increasingly popular use in such settings. Methods: We retrospectively examined medical records at the Maricopa Integrated Health Systems Emergency Department to find 100 instances between February 2014 and September 2014 in which a patient had electrolyte testing performed on both the i‐STAT and in the central laboratory within a 60 minute timeframe. These data were examined using variance of means and Bland‐Altman graphing for equivalency. Results: We set the clinical equivalence threshold for each lab to be 5% of the mean normal value. That is, if the i‐STAT differed from central lab by less than 5% of the middle of the normal range (137‐145 for sodium, 5% of which is 7) then we consider them to be clinically equivalent. At this level we were unable to show clinical equivalence. In additional, all electrolytes tested showed small but significant bias between the i‐STAT and the central laboratory. Re‐examination of the data excluding all measurements more than 15 minutes apart showed similar findings. Conclusions: At this time we cannot show equivalency between the i‐STAT device and the central laboratory when used under real‐life emergency department conditions. More research is needed is to support or refute these findings.


Files in this item

Thumbnail
Name:
Little, Colin.pdf
Size:
562.6Kb
Format:
PDF
Description:
Thesis
Thumbnail
Name:
Little, Colin Poster.pdf
Size:
175.5Kb
Format:
PDF
Description:
Poster

This item appears in the following Collection(s)

Show simple item record