    System and Method for Comparison and Training of Mechanical Circulatory Support Devices: A Patient Independent Platform Using the Total Artificial Heart and Donovan Mock Circulation System

    • CSV
    • RefMan
    • EndNote
    • BibTex
    • RefWorks
    Thumbnail
    Name:
    azu_etd_13878_sip1_m.pdf
    Size:
    1.529Mb
    Format:
    PDF
    Download
    Author
    DeCook, Katrina Jolene
    Issue Date
    2015
    Keywords
    heart failure
    HQ curve
    mock circulation system
    training tool
    ventricular assist device
    Biomedical Engineering
    artificial heart
    Advisor
    Slepian, Marvin J.
    
    Metadata
    Show full item record
    Publisher
    The University of Arizona.
    Rights
    Copyright © is held by the author. Digital access to this material is made possible by the University Libraries, University of Arizona. Further transmission, reproduction or presentation (such as public display or performance) of protected items is prohibited except with permission of the author.
    Abstract
    Mechanical circulatory support (MCS) is a viable therapy for end stage heart failure. However, despite clinical success, the ability to compare MCS devices in vitro and perform training scenarios is extremely limited. Comparative studies are limited as different devices cannot be interchanged in a patient due to the surgical nature of implant. Further, training and failure scenarios cannot be performed on patients with devices as this would subject a patient to a failure mode. A need exists for a readily available mock system that can perform comparative testing and training scenarios with MCS devices. Previously, our group has fabricated a well characterized mock circulation system consisting of a SynCardia temporary Total Artificial Heart (TAH) and Donovan Mock Circulation tank (DMC tank). Further, utilizing this system with the TAH operating in reduced output mode, a heart failure model was developed. In the present study, three ventricular assist devices (VADs) were independently attached to the heart failure model to compare device performances over a range of preloads and afterloads. In addition, specific clinical scenarios were created with the system to analyze how VAD-displayed waveforms from the system correlate with clinical scenarios. Finally, each VAD was powered off while attached to the heart failure model to compare fluid flow through the VAD in a pump-failure scenario. We demonstrated that this system can successfully be utilized to compare MCS devices (i.e. ventricular assist devices) and for successful training of patients and clinicians.
    Type
    text
    Electronic Thesis
    Degree Name
    M.S.
    Degree Level
    masters
    Degree Program
    Graduate College
    Biomedical Engineering
    Degree Grantor
    University of Arizona
    Collections
    Master's Theses

    entitlement

     
    The University of Arizona Libraries | 1510 E. University Blvd. | Tucson, AZ 85721-0055
    Tel 520-621-6442 | repository@u.library.arizona.edu
    DSpace software copyright © 2002-2017  DuraSpace
    Quick Guide | Contact Us | Send Feedback
    Open Repository is a service operated by 
    Atmire NV
     

    Export search results

    The export option will allow you to export the current search results of the entered query to a file. Different formats are available for download. To export the items, click on the button corresponding with the preferred download format.

    By default, clicking on the export buttons will result in a download of the allowed maximum amount of items.

    To select a subset of the search results, click "Selective Export" button and make a selection of the items you want to export. The amount of items that can be exported at once is similarly restricted as the full export.

    After making a selection, click one of the export format buttons. The amount of items that will be exported is indicated in the bubble next to export format.