dc.descriptionITC/USA 2014 Conference Proceedings / The Fiftieth Annual International Telemetering Conference and Technical Exhibition / October 20-23, 2014 / Town and Country Resort & Convention Center, San Diego, CAen_US
dc.description.abstractOne of the initial control room capabilities to be demonstrated by iNET program is the ability to provide data displays in the control room that do not contain data dropouts. This concept is called PCM Backfill where PCM data is both transmitted via traditional SST and recorded onboard via an iNET compatible recorder. When data dropouts occur, data requests are made over the telemetry network to the recorder for the missing portions of the PCM data stream. The retrieved data is sent over the telemetry network to the backfill application and ultimately delivered to a pristine data display. The integration of traditional SST and the PCM Backfill capability provides both real-time safety of flight data side-by-side with pristine data suitable for advanced analysis.
dc.description.sponsorshipInternational Foundation for Telemeteringen
dc.language.isoen_USen
dc.publisherInternational Foundation for Telemeteringen
dc.relation.urlhttp://www.telemetry.org/en
dc.rightsCopyright © held by the author; distribution rights International Foundation for Telemeteringen_US
dc.subjectPulse Code Modulation (PCM)en
dc.subjectnetworken
dc.subjectwirelessen
dc.subjecttelemetryen
dc.subjectdata processingen
dc.subjectTelemetry Network System (TmNS)en
dc.subjectintegrated Network Enhanced Telemetry (iNET)en
dc.subjectTransmission Control Protocol (TCP)en
dc.subjectrecorderen
dc.subjectEnhanced Query Data Recorder (EQDR)en
dc.titlePCM Backfill: Providing PCM to the Control Room Without Dropoutsen_US
dc.typetexten
dc.typeProceedingsen
dc.contributor.departmentEdwards Air Force Baseen
dc.identifier.journalInternational Telemetering Conference Proceedingsen
dc.description.collectioninformationProceedings from the International Telemetering Conference are made available by the International Foundation for Telemetering and the University of Arizona Libraries. Visit http://www.telemetry.org/index.php/contact-us if you have questions about items in this collection.en_US
refterms.dateFOA2018-04-26T01:41:26Z
html.description.abstractOne of the initial control room capabilities to be demonstrated by iNET program is the ability to provide data displays in the control room that do not contain data dropouts. This concept is called PCM Backfill where PCM data is both transmitted via traditional SST and recorded onboard via an iNET compatible recorder. When data dropouts occur, data requests are made over the telemetry network to the recorder for the missing portions of the PCM data stream. The retrieved data is sent over the telemetry network to the backfill application and ultimately delivered to a pristine data display. The integration of traditional SST and the PCM Backfill capability provides both real-time safety of flight data side-by-side with pristine data suitable for advanced analysis.