Show simple item record

dc.contributor.authorLeite, Nelson Paiva Oliveira
dc.contributor.authorSousa, Lucas Benedito dos Reis
dc.date.accessioned2015-11-03T20:02:36Zen
dc.date.available2015-11-03T20:02:36Zen
dc.date.issued2012-10en
dc.identifier.issn0884-5123en
dc.identifier.issn0074-9079en
dc.identifier.urihttp://hdl.handle.net/10150/581678en
dc.descriptionITC/USA 2012 Conference Proceedings / The Forty-Eighth Annual International Telemetering Conference and Technical Exhibition / October 22-25, 2012 / Town and Country Resort & Convention Center, San Diego, Californiaen_US
dc.description.abstractThe execution of experimental Flight Test Campaign (FTC) provides all information required for the aircraft operation and certification. Nowadays all information gathered during a FTC is provided by the Flight Test Instrumentation System (FTI) that is basically a measurement system. Typically for all FTI parameters, the estimation of the calibration coefficients that minimizes most of systematic errors and its associated uncertainty is carried out by a Static Calibration Process. To execute this task the Brazilian Institute of Research and Flight Test (Instituto de Pesquisa e Ensaios em Voo - IPEV) developed the Sistema de Automação do Laboratório de Ensaios em Voo (SALEV©) which is fully compliant with the calibration and uncertainty expression standards. For some parameters (i.e. Static Pressure) the sensor installation particularities (i.e. Pressure tapping) introduces low pass filtering characteristics into the measurement chain. In this case the measurement accuracy will be jeopardized when executing high-dynamic test points (i.e. Spin Tests). To overcome this issue the IPEV research and development group introduced a dynamic calibration process for flight test parameters that requires the knowledge of the actual Transfer Function (TF). The problem now is to simulate an impulsive input for the TF characterization which is too complex. To solve this issue a new calibration procedure was developed and evaluated for the determination of the FTI dynamic response. SALEV© was used to simulate a step input instead of an impulse. Then filtered and unfiltered data was properly compared for the determination of the TF. Preliminary test results show satisfactory performance.
dc.description.sponsorshipInternational Foundation for Telemeteringen
dc.language.isoen_USen
dc.publisherInternational Foundation for Telemeteringen
dc.relation.urlhttp://www.telemetry.org/en
dc.rightsCopyright © held by the author; distribution rights International Foundation for Telemeteringen_US
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/
dc.subjectFlight Testsen
dc.subjectDynamic Calibrationen
dc.subjectUncertaintyen
dc.subjectPressureen
dc.titleThe Design of Dynamic Calibration Procedureen_US
dc.typetexten
dc.typeProceedingsen
dc.contributor.departmentInstituto de Pesquisas e Ensaios em Vooen
dc.identifier.journalInternational Telemetering Conference Proceedingsen
dc.description.collectioninformationProceedings from the International Telemetering Conference are made available by the International Foundation for Telemetering and the University of Arizona Libraries. Visit http://www.telemetry.org/index.php/contact-us if you have questions about items in this collection.en_US
refterms.dateFOA2018-04-26T18:33:54Z
html.description.abstractThe execution of experimental Flight Test Campaign (FTC) provides all information required for the aircraft operation and certification. Nowadays all information gathered during a FTC is provided by the Flight Test Instrumentation System (FTI) that is basically a measurement system. Typically for all FTI parameters, the estimation of the calibration coefficients that minimizes most of systematic errors and its associated uncertainty is carried out by a Static Calibration Process. To execute this task the Brazilian Institute of Research and Flight Test (Instituto de Pesquisa e Ensaios em Voo - IPEV) developed the Sistema de Automação do Laboratório de Ensaios em Voo (SALEV©) which is fully compliant with the calibration and uncertainty expression standards. For some parameters (i.e. Static Pressure) the sensor installation particularities (i.e. Pressure tapping) introduces low pass filtering characteristics into the measurement chain. In this case the measurement accuracy will be jeopardized when executing high-dynamic test points (i.e. Spin Tests). To overcome this issue the IPEV research and development group introduced a dynamic calibration process for flight test parameters that requires the knowledge of the actual Transfer Function (TF). The problem now is to simulate an impulsive input for the TF characterization which is too complex. To solve this issue a new calibration procedure was developed and evaluated for the determination of the FTI dynamic response. SALEV© was used to simulate a step input instead of an impulse. Then filtered and unfiltered data was properly compared for the determination of the TF. Preliminary test results show satisfactory performance.


Files in this item

Thumbnail
Name:
ITC_2012_12-13-05.pdf
Size:
1.152Mb
Format:
PDF

This item appears in the following Collection(s)

Show simple item record