Show simple item record

dc.contributor.authorCorry, Diarmuid
dc.date.accessioned2016-04-01T18:27:47Zen
dc.date.available2016-04-01T18:27:47Zen
dc.date.issued2006-10en
dc.identifier.issn0884-5123en
dc.identifier.issn0074-9079en
dc.identifier.urihttp://hdl.handle.net/10150/604243en
dc.descriptionITC/USA 2006 Conference Proceedings / The Forty-Second Annual International Telemetering Conference and Technical Exhibition / October 23-26, 2006 / Town and Country Resort & Convention Center, San Diego, Californiaen_US
dc.description.abstractOne of the problems for manufacturers and users of flight test data acquisition equipment, is to guarantee synchronization between multiple units acquiring data on the vehicle. Past solutions have involved proprietary interconnects and multiple wire installations increasing weight and complexity and reducing inter-operation of units. This problem has become particularly important given the trend towards commercial busses, especially Ethernet, as a system interconnect. The IEEE1588 standard offers a way to transmitting time accurately over Ethernet. This paper discusses the standard, how it might be implemented, and examines the issues involved in adopting this standard for flight test data acquisition. A particular implementation that results in a synchronized four-wire Ethernet based distributed data acquisition system is discussed in section 3.
dc.description.sponsorshipInternational Foundation for Telemeteringen
dc.language.isoen_USen
dc.publisherInternational Foundation for Telemeteringen
dc.relation.urlhttp://www.telemetry.org/en
dc.rightsCopyright © International Foundation for Telemeteringen
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/
dc.subjectTime Synchronizationen
dc.subjectData Acquisitionen
dc.subjectPTPen
dc.subjectEtherneten
dc.subjectSynchronous samplingen
dc.titleIEEE1588 – A solution for synchronization of networked data acquisition systems?en_US
dc.typetexten
dc.typeProceedingsen
dc.contributor.departmentACRA CONTROL INCen
dc.identifier.journalInternational Telemetering Conference Proceedingsen
dc.description.collectioninformationProceedings from the International Telemetering Conference are made available by the International Foundation for Telemetering and the University of Arizona Libraries. Visit http://www.telemetry.org/index.php/contact-us if you have questions about items in this collection.en
refterms.dateFOA2018-09-03T07:44:14Z
html.description.abstractOne of the problems for manufacturers and users of flight test data acquisition equipment, is to guarantee synchronization between multiple units acquiring data on the vehicle. Past solutions have involved proprietary interconnects and multiple wire installations increasing weight and complexity and reducing inter-operation of units. This problem has become particularly important given the trend towards commercial busses, especially Ethernet, as a system interconnect. The IEEE1588 standard offers a way to transmitting time accurately over Ethernet. This paper discusses the standard, how it might be implemented, and examines the issues involved in adopting this standard for flight test data acquisition. A particular implementation that results in a synchronized four-wire Ethernet based distributed data acquisition system is discussed in section 3.