Show simple item record

dc.contributor.authorWanis, Paul
dc.date.accessioned2016-04-05T17:27:26Zen
dc.date.available2016-04-05T17:27:26Zen
dc.date.issued2007-10en
dc.identifier.issn0884-5123en
dc.identifier.issn0074-9079en
dc.identifier.urihttp://hdl.handle.net/10150/604537en
dc.descriptionITC/USA 2007 Conference Proceedings / The Forty-Third Annual International Telemetering Conference and Technical Exhibition / October 22-25, 2007 / Riviera Hotel & Convention Center, Las Vegas, Nevadaen_US
dc.description.abstractThermocouple measurements require “cold junction” compensation in order to obtain a correct reading. This compensation has traditionally been done with custom circuitry. In flight test applications where volume and power are at a premium (e.g. weapons flight test) it is desirable to have a more flexible solution that uses standard analog data acquisition channels already available as part of the encoder circuitry and performs compensation with remote software. This can be done via digital compensation, but certain measures must be taken to maintain accuracy and minimize noise. This paper describes some of these techniques and their performance tradeoffs.
dc.description.sponsorshipInternational Foundation for Telemeteringen
dc.language.isoen_USen
dc.publisherInternational Foundation for Telemeteringen
dc.relation.urlhttp://www.telemetry.org/en
dc.rightsCopyright © held by the author; distribution rights International Foundation for Telemeteringen
dc.subjectThermocoupleen
dc.subjectCold Junctionen
dc.subjectCompensationen
dc.subjectNoise Correlationen
dc.titleThermocouple Measurements without Custom Electronicsen_US
dc.typetexten
dc.typeProceedingsen
dc.contributor.departmentL-3 Communications Telemetry & RF Productsen
dc.identifier.journalInternational Telemetering Conference Proceedingsen
dc.description.collectioninformationProceedings from the International Telemetering Conference are made available by the International Foundation for Telemetering and the University of Arizona Libraries. Visit http://www.telemetry.org/index.php/contact-us if you have questions about items in this collection.en
refterms.dateFOA2018-06-14T16:07:39Z
html.description.abstractThermocouple measurements require “cold junction” compensation in order to obtain a correct reading. This compensation has traditionally been done with custom circuitry. In flight test applications where volume and power are at a premium (e.g. weapons flight test) it is desirable to have a more flexible solution that uses standard analog data acquisition channels already available as part of the encoder circuitry and performs compensation with remote software. This can be done via digital compensation, but certain measures must be taken to maintain accuracy and minimize noise. This paper describes some of these techniques and their performance tradeoffs.


Files in this item

Thumbnail
Name:
ITC_2007_07-10-04.pdf
Size:
165.1Kb
Format:
PDF

This item appears in the following Collection(s)

Show simple item record