Show simple item record

dc.contributor.authorBenitez, Jesus
dc.contributor.authorGuadiana, Juan
dc.contributor.authorTorres, Miguel
dc.contributor.authorCreel, Larry
dc.date.accessioned2016-04-07T16:57:45Zen
dc.date.available2016-04-07T16:57:45Zen
dc.date.issued2006-10en
dc.identifier.issn0884-5123en
dc.identifier.issn0074-9079en
dc.identifier.urihttp://hdl.handle.net/10150/604753en
dc.descriptionITC/USA 2006 Conference Proceedings / The Forty-Second Annual International Telemetering Conference and Technical Exhibition / October 23-26, 2006 / Town and Country Resort & Convention Center, San Diego, Californiaen_US
dc.description.abstractThe software decommutator was recently fielded at White Sands to address the requirements of a new missile test program. This software decommutator is rewritten as a simple C program Function or Class with a simple interface. The function and an Interface Control Definition (ICD) comprise the SoftDecom Engine (SDE). This paper addresses how an SDE can deliver Enterprise Wide Portability, not only that of the SDE, but more importantly a test program!s Verification & Validation (V&V). The crux of the portability issue is reduced to defining the interface of the SDE. In the simplest manifestation only two interfaces are needed and one is a given. The input structure is defined by the telemeter minor frame with time appended if desired. The output structure is no more than an array containing the parameters required. The ICD could be generalized into a standard for most applications, but that isn!t necessary, as the structures are simple, hence easy to adapt to anyway. This new paradigm!s importance will flourish on industries irreversible migration to faster and more complex telemeters. The paper reviews the relative ease that software exhibits when addressing very complex telemeters. With confidence it may be said “ if the telemeter format can be described in writing, it can be processed real time”. Also discussed are tasks that normally require specialized or customized and expensive equipment for example, merged streams, complex simulations and recording and reproducing PCM (sans recorder). Hopefully, your creativity will be engaged as ours has been.
dc.description.sponsorshipInternational Foundation for Telemeteringen
dc.language.isoen_USen
dc.publisherInternational Foundation for Telemeteringen
dc.relation.urlhttp://www.telemetry.org/en
dc.rightsCopyright © International Foundation for Telemeteringen
dc.subjectSoftware Decommutationen
dc.subjectTM over IPen
dc.subjectPortabilityen
dc.subjectV&Ven
dc.subjectCommon Frame Architectureen
dc.subjectEnterprise Architectureen
dc.subjectintegrated Telemetry Data Center (iTDC)en
dc.titleThe SoftDecom Engineen_US
dc.typetexten
dc.typeProceedingsen
dc.contributor.departmentWhite Sands Missile Rangeen
dc.identifier.journalInternational Telemetering Conference Proceedingsen
dc.description.collectioninformationProceedings from the International Telemetering Conference are made available by the International Foundation for Telemetering and the University of Arizona Libraries. Visit http://www.telemetry.org/index.php/contact-us if you have questions about items in this collection.en
refterms.dateFOA2018-06-15T21:43:42Z
html.description.abstractThe software decommutator was recently fielded at White Sands to address the requirements of a new missile test program. This software decommutator is rewritten as a simple C program Function or Class with a simple interface. The function and an Interface Control Definition (ICD) comprise the SoftDecom Engine (SDE). This paper addresses how an SDE can deliver Enterprise Wide Portability, not only that of the SDE, but more importantly a test program!s Verification & Validation (V&V). The crux of the portability issue is reduced to defining the interface of the SDE. In the simplest manifestation only two interfaces are needed and one is a given. The input structure is defined by the telemeter minor frame with time appended if desired. The output structure is no more than an array containing the parameters required. The ICD could be generalized into a standard for most applications, but that isn!t necessary, as the structures are simple, hence easy to adapt to anyway. This new paradigm!s importance will flourish on industries irreversible migration to faster and more complex telemeters. The paper reviews the relative ease that software exhibits when addressing very complex telemeters. With confidence it may be said “ if the telemeter format can be described in writing, it can be processed real time”. Also discussed are tasks that normally require specialized or customized and expensive equipment for example, merged streams, complex simulations and recording and reproducing PCM (sans recorder). Hopefully, your creativity will be engaged as ours has been.