Show simple item record

dc.contributor.authorWallman, Andrew
dc.date.accessioned2016-04-20T23:08:05Zen
dc.date.available2016-04-20T23:08:05Zen
dc.date.issued2016-04-20
dc.identifier.urihttp://hdl.handle.net/10150/606216
dc.descriptionA Thesis submitted to The University of Arizona College of Medicine - Phoenix in partial fulfillment of the requirements for the Degree of Doctor of Medicine.en
dc.description.abstractWe present the safety and efficacy of a novel transscleral sutured posterior chamber intraocular lens (TSSPCIOL) implantation approach utilizing 25 gauge vitrectomy and a foldable posterior chamber intraocular lens implant (AKREOS AO60, Bausch & Lomb). 80 consecutive eyes that underwent single surgeon TSSPCIOL implantation between October 2008 and July 2012 at a referral‐based retina institution were analyzed for best spectacle‐corrected visual acuity (BCVA) and safety indicators. Postoperative complications included retinal detachment in 2 eyes (2.5%), Irvine‐Gass cystoid macular edema in 3 eyes (3.75%), with 2 of those cases occurring late, persistent postoperative corneal edema in 1 eye (1.25%), hyphema in 2 eyes (2.5%) and 1 case of postoperative vitreous hemorrhage with spontaneous clearing. The modified external approach with AKREOS® TSSPCIOL placement with 25 gauge vitrectomy has relatively few complications, improves visual acuity in patients requiring TSSPCIOL, and offers several advantages over traditional anterior chamber or conventional scleral sutured techniques.
dc.language.isoen_USen
dc.publisherThe University of Arizona.en_US
dc.rightsCopyright © is held by the author. Digital access to this material is made possible by the College of Medicine - Phoenix, University of Arizona. Further transmission, reproduction or presentation (such as public display or performance) of protected items is prohibited except with permission of the author.en_US
dc.subjecttransscleral sutured posterior chamberen
dc.subjectiolen
dc.subject.meshLenses, Intraocularen
dc.subject.meshScleral Diseasesen
dc.subject.meshScleraen
dc.titleSafety and Visual Outcomes of Novel Abexterno Akreos® Single Pass Method of Transscleral Sutured Posterior Chamber IOL Implantation for Scleral Fixation of IOLen_US
dc.typetext; Electronic Thesisen
dc.contributor.departmentThe University of Arizona College of Medicine - Phoenixen
dc.description.collectioninformationThis item is part of the College of Medicine - Phoenix Scholarly Projects 2016 collection. For more information, contact the Phoenix Biomedical Campus Library at pbc-library@email.arizona.edu.en_US
dc.contributor.mentorMonson, Bryanen
html.description.abstractWe present the safety and efficacy of a novel transscleral sutured posterior chamber intraocular lens (TSSPCIOL) implantation approach utilizing 25 gauge vitrectomy and a foldable posterior chamber intraocular lens implant (AKREOS AO60, Bausch & Lomb). 80 consecutive eyes that underwent single surgeon TSSPCIOL implantation between October 2008 and July 2012 at a referral‐based retina institution were analyzed for best spectacle‐corrected visual acuity (BCVA) and safety indicators. Postoperative complications included retinal detachment in 2 eyes (2.5%), Irvine‐Gass cystoid macular edema in 3 eyes (3.75%), with 2 of those cases occurring late, persistent postoperative corneal edema in 1 eye (1.25%), hyphema in 2 eyes (2.5%) and 1 case of postoperative vitreous hemorrhage with spontaneous clearing. The modified external approach with AKREOS® TSSPCIOL placement with 25 gauge vitrectomy has relatively few complications, improves visual acuity in patients requiring TSSPCIOL, and offers several advantages over traditional anterior chamber or conventional scleral sutured techniques.


Files in this item

Thumbnail
Name:
Wallman_Thesis.pdf
Size:
432.3Kb
Format:
PDF
Thumbnail
Name:
Wallmann_Poster.pdf
Size:
161.5Kb
Format:
PDF

This item appears in the following Collection(s)

Show simple item record