Effects of Instrumentation Recorder time Base Error on Spectral Purity
| dc.contributor.author | Leeke, P. D. | |
| dc.date.accessioned | 2016-04-22T21:18:17Z | en |
| dc.date.available | 2016-04-22T21:18:17Z | en |
| dc.date.issued | 1970-10 | en |
| dc.identifier.issn | 0884-5123 | en |
| dc.identifier.issn | 0074-9079 | en |
| dc.identifier.uri | http://hdl.handle.net/10150/606769 | en |
| dc.description | International Telemetering Conference Proceedings / October 13-15, 1970 / International Hotel, Los Angeles, California | en_US |
| dc.description.abstract | Experimental data is presented to show how carrier amplitude of a recorded signal is affected by Time Base Error. Time Base Error effects on the sideband structure of a recorded signal are also shown for different amounts of Time Base Error and at several frequencies. The effect of capstan servo adjustment on spectral purity demonstrates the need for new methods of performance evaluation to achieve optimum performance when recording spectrum information. The data presented shows that skew (ITDE) has little effect on spectral purity for analysis bandwidths of 50 Hz or greater. | |
| dc.description.sponsorship | International Foundation for Telemetering | en |
| dc.language.iso | en_US | en |
| dc.publisher | International Foundation for Telemetering | en |
| dc.relation.url | http://www.telemetry.org/ | en |
| dc.rights | Copyright © International Foundation for Telemetering | en |
| dc.rights.uri | http://rightsstatements.org/vocab/InC/1.0/ | |
| dc.title | Effects of Instrumentation Recorder time Base Error on Spectral Purity | en_US |
| dc.type | text | en |
| dc.type | Proceedings | en |
| dc.contributor.department | Minnesota Mining and Manufacturing Company | en |
| dc.identifier.journal | International Telemetering Conference Proceedings | en |
| dc.description.collectioninformation | Proceedings from the International Telemetering Conference are made available by the International Foundation for Telemetering and the University of Arizona Libraries. Visit http://www.telemetry.org/index.php/contact-us if you have questions about items in this collection. | en |
| refterms.dateFOA | 2018-09-11T09:28:45Z | |
| html.description.abstract | Experimental data is presented to show how carrier amplitude of a recorded signal is affected by Time Base Error. Time Base Error effects on the sideband structure of a recorded signal are also shown for different amounts of Time Base Error and at several frequencies. The effect of capstan servo adjustment on spectral purity demonstrates the need for new methods of performance evaluation to achieve optimum performance when recording spectrum information. The data presented shows that skew (ITDE) has little effect on spectral purity for analysis bandwidths of 50 Hz or greater. |
