Show simple item record

dc.contributor.authorHeideman, W. R.
dc.contributor.authorNichols, M. H.
dc.date.accessioned2016-04-25T16:30:48Zen
dc.date.available2016-04-25T16:30:48Zen
dc.date.issued1970-10en
dc.identifier.issn0884-5123en
dc.identifier.issn0074-9079en
dc.identifier.urihttp://hdl.handle.net/10150/606989en
dc.descriptionInternational Telemetering Conference Proceedings / October 13-15, 1970 / International Hotel, Los Angeles, Californiaen_US
dc.description.abstractNotch power ratio tests were performed on a magnetic tape recorder/ reproducer, using direct recording in the baseband. For the equipment tested, it is concluded that the IRIG method of setting the record power level as that which produces 1% third harmonic on a single tone, does not necessarily result in an optimum record/reproduce cycle. It is concluded that the input and output levels should be set with reference to notch noise test data to optimize baseband tape recording performance for baseband recording of frequency division multiplexed systems. In order to interpret the notch noise data, it was necessary to assume two non-linear processes, one acting in conjunction with the record process and one in conjunction with the playback process.
dc.description.sponsorshipInternational Foundation for Telemeteringen
dc.language.isoen_USen
dc.publisherInternational Foundation for Telemeteringen
dc.relation.urlhttp://www.telemetry.org/en
dc.rightsCopyright © International Foundation for Telemeteringen
dc.titleNotch Noise Loading Data on Baseband Tape Recordingen_US
dc.typetexten
dc.typeProceedingsen
dc.contributor.departmentAerospace Corporationen
dc.identifier.journalInternational Telemetering Conference Proceedingsen
dc.description.collectioninformationProceedings from the International Telemetering Conference are made available by the International Foundation for Telemetering and the University of Arizona Libraries. Visit http://www.telemetry.org/index.php/contact-us if you have questions about items in this collection.en
refterms.dateFOA2018-06-14T16:42:33Z
html.description.abstractNotch power ratio tests were performed on a magnetic tape recorder/ reproducer, using direct recording in the baseband. For the equipment tested, it is concluded that the IRIG method of setting the record power level as that which produces 1% third harmonic on a single tone, does not necessarily result in an optimum record/reproduce cycle. It is concluded that the input and output levels should be set with reference to notch noise test data to optimize baseband tape recording performance for baseband recording of frequency division multiplexed systems. In order to interpret the notch noise data, it was necessary to assume two non-linear processes, one acting in conjunction with the record process and one in conjunction with the playback process.