CONVERTING ASYNCHRONOUS DATA INTO A STANDARD IRIG TELEMETRY FORMAT
Rights
Copyright © International Foundation for TelemeteringCollection Information
Proceedings from the International Telemetering Conference are made available by the International Foundation for Telemetering and the University of Arizona Libraries. Visit http://www.telemetry.org/index.php/contact-us if you have questions about items in this collection.Abstract
In recent years we have seen an increase in the use of MIL-STD-1553 buses and other asynchronous data sources used in new missile and launcher designs. The application of multiplexed asynchronous buses in missiles and launchers is very common today. With increasing application of asynchronous data sources into very complex systems the need to acquire, analyze, and present one hundred percent of the bus traffic in real time or near real time has become especially important during testing and diagnostic operations. This paper discusses ways of converting asynchronous data, including MIL-STD-1553, into a telemetry format that is suitable for encryption, telemetering, recording, and presenting with Inter Range Instrumentation Group (IRIG) compatible off-the-shelf hardware. The importance of these designs is to provide the capability to conserve data bandwidth and to maximize the use of existing hardware. In addition, this paper will discuss a unique decode and time tagging design that conserves data storage when compared to the methods in IRIG Standard 106-96 and still maintains a very accurate time tag.Sponsors
International Foundation for TelemeteringISSN
0884-51230074-9079