Affiliation
University of NevadaSandia National Labs
Issue Date
1983-10
Metadata
Show full item recordRights
Copyright © International Foundation for TelemeteringCollection Information
Proceedings from the International Telemetering Conference are made available by the International Foundation for Telemetering and the University of Arizona Libraries. Visit http://www.telemetry.org/index.php/contact-us if you have questions about items in this collection.Abstract
PCM data at the Tonopah Test Range (TTR) is processed and displayed in real-time on a Perkin-Elmer 8/32-D computer system. Up to four links can be processed concurrently, with input data coming from telemetry PCM/PAM decommutators and multichannel ADC systems. Special software is used to strip out an embedded PCM format and input the data as a simulated PCM link. Off-line interactive programs are used to specify the PCM data format and create the displays. This capability allows a wide variety of PCM formats to be specified, and displays can be easily configured to fit testing requirements.Sponsors
International Foundation for TelemeteringISSN
0884-51230074-9079