REAL-TIME PCM PROCESSING AT THE TONOPAH TEST RANGE
| dc.contributor.author | Sherman, Stephen | |
| dc.contributor.author | Tebbs, J Daniel | |
| dc.date.accessioned | 2016-06-10T23:00:21Z | |
| dc.date.available | 2016-06-10T23:00:21Z | |
| dc.date.issued | 1983-10 | |
| dc.identifier.issn | 0884-5123 | |
| dc.identifier.issn | 0074-9079 | |
| dc.identifier.uri | http://hdl.handle.net/10150/612583 | |
| dc.description | International Telemetering Conference Proceedings / October 24-27, 1983 / Sheraton-Harbor Island Hotel and Convention Center, San Diego, California | en_US |
| dc.description.abstract | PCM data at the Tonopah Test Range (TTR) is processed and displayed in real-time on a Perkin-Elmer 8/32-D computer system. Up to four links can be processed concurrently, with input data coming from telemetry PCM/PAM decommutators and multichannel ADC systems. Special software is used to strip out an embedded PCM format and input the data as a simulated PCM link. Off-line interactive programs are used to specify the PCM data format and create the displays. This capability allows a wide variety of PCM formats to be specified, and displays can be easily configured to fit testing requirements. | |
| dc.description.sponsorship | International Foundation for Telemetering | en |
| dc.language.iso | en_US | en |
| dc.publisher | International Foundation for Telemetering | en |
| dc.relation.url | http://www.telemetry.org/ | en |
| dc.rights | Copyright © International Foundation for Telemetering | en |
| dc.rights.uri | http://rightsstatements.org/vocab/InC/1.0/ | |
| dc.title | REAL-TIME PCM PROCESSING AT THE TONOPAH TEST RANGE | en_US |
| dc.type | text | en |
| dc.type | Proceedings | en |
| dc.contributor.department | University of Nevada | en |
| dc.contributor.department | Sandia National Labs | en |
| dc.identifier.journal | International Telemetering Conference Proceedings | en |
| dc.description.collectioninformation | Proceedings from the International Telemetering Conference are made available by the International Foundation for Telemetering and the University of Arizona Libraries. Visit http://www.telemetry.org/index.php/contact-us if you have questions about items in this collection. | en |
| refterms.dateFOA | 2018-05-28T16:14:24Z | |
| html.description.abstract | PCM data at the Tonopah Test Range (TTR) is processed and displayed in real-time on a Perkin-Elmer 8/32-D computer system. Up to four links can be processed concurrently, with input data coming from telemetry PCM/PAM decommutators and multichannel ADC systems. Special software is used to strip out an embedded PCM format and input the data as a simulated PCM link. Off-line interactive programs are used to specify the PCM data format and create the displays. This capability allows a wide variety of PCM formats to be specified, and displays can be easily configured to fit testing requirements. |