TRANSMISSION OF THERMAL IMAGE DATA USING PLUSE CODE MODULATION*
dc.contributor.author | Johnson, F. Bruce | |
dc.date.accessioned | 2016-06-15T20:54:51Z | |
dc.date.available | 2016-06-15T20:54:51Z | |
dc.date.issued | 1982-09 | |
dc.identifier.issn | 0884-5123 | |
dc.identifier.issn | 0074-9079 | |
dc.identifier.uri | http://hdl.handle.net/10150/613293 | |
dc.description | International Telemetering Conference Proceedings / September 28-30, 1982 / Sheraton Harbor Island Hotel and Convention Center, San Diego, California | en_US |
dc.description.abstract | This paper presents a method for synchronous conversion of infra -red image data to a Pulse-Code Modulation (PCM) bit stream for recording on instrumentation tape recorders. The PCM data recording method provides an improvement over analog FM recording in signal to noise ratio, horizontal resolution, and speed of data formatting. The methodology was applied to the design of a PCM encoder for an AGA model 680 Thermovision camera. The extension of the design to other devices is discussed. Considerations for the display of real-time and reduced speed data display on conventional television monitors are presented. | |
dc.description.sponsorship | International Foundation for Telemetering | en |
dc.language.iso | en_US | en |
dc.publisher | International Foundation for Telemetering | en |
dc.relation.url | http://www.telemetry.org/ | en |
dc.rights | Copyright © International Foundation for Telemetering | en |
dc.rights.uri | http://rightsstatements.org/vocab/InC/1.0/ | |
dc.title | TRANSMISSION OF THERMAL IMAGE DATA USING PLUSE CODE MODULATION* | en_US |
dc.type | text | en |
dc.type | Proceedings | en |
dc.contributor.department | Colorado Video, Inc. | en |
dc.identifier.journal | International Telemetering Conference Proceedings | en |
dc.description.collectioninformation | Proceedings from the International Telemetering Conference are made available by the International Foundation for Telemetering and the University of Arizona Libraries. Visit http://www.telemetry.org/index.php/contact-us if you have questions about items in this collection. | en |
refterms.dateFOA | 2018-09-11T13:09:18Z | |
html.description.abstract | This paper presents a method for synchronous conversion of infra -red image data to a Pulse-Code Modulation (PCM) bit stream for recording on instrumentation tape recorders. The PCM data recording method provides an improvement over analog FM recording in signal to noise ratio, horizontal resolution, and speed of data formatting. The methodology was applied to the design of a PCM encoder for an AGA model 680 Thermovision camera. The extension of the design to other devices is discussed. Considerations for the display of real-time and reduced speed data display on conventional television monitors are presented. |