Show simple item record

dc.contributor.authorTalmadge, Richard D.
dc.contributor.authorRadmand, Mansour
dc.date.accessioned2016-06-30T18:36:50Z
dc.date.available2016-06-30T18:36:50Z
dc.date.issued1988-10
dc.identifier.issn0884-5123
dc.identifier.issn0074-9079
dc.identifier.urihttp://hdl.handle.net/10150/615219
dc.descriptionInternational Telemetering Conference Proceedings / October 17-20, 1988 / Riviera Hotel, Las Vegas, Nevadaen_US
dc.description.abstractAir Force systems testing today requires that more and more data be acquired to a higher degree of accuracy and in fewer flights. This necessitates a new approach to dynamic data acquisition system design. In the past data acquisition organizations used either direct or FM recording techniques of one sort or another to acquire data for post test processing. This paper will outline the direction that this organization is taking to reduce the size of the installed system as well as the time and money required to maintain the system during the testing process. The system discussed provides a capability to acquire both static (DC) data and dynamic data up to 10,000 Hertz and has a dynamic range in excess of 120 dB.
dc.description.sponsorshipInternational Foundation for Telemeteringen
dc.language.isoen_USen
dc.publisherInternational Foundation for Telemeteringen
dc.relation.urlhttp://www.telemetry.org/en
dc.rightsCopyright © International Foundation for Telemeteringen
dc.titleHigh Speed Data Acquisition Systemsen_US
dc.typetexten
dc.typeProceedingsen
dc.contributor.departmentWright-Patterson Air Force Baseen
dc.contributor.departmentAydin Vector Divisionen
dc.identifier.journalInternational Telemetering Conference Proceedingsen
dc.description.collectioninformationProceedings from the International Telemetering Conference are made available by the International Foundation for Telemetering and the University of Arizona Libraries. Visit http://www.telemetry.org/index.php/contact-us if you have questions about items in this collection.en
refterms.dateFOA2018-08-14T13:03:51Z
html.description.abstractAir Force systems testing today requires that more and more data be acquired to a higher degree of accuracy and in fewer flights. This necessitates a new approach to dynamic data acquisition system design. In the past data acquisition organizations used either direct or FM recording techniques of one sort or another to acquire data for post test processing. This paper will outline the direction that this organization is taking to reduce the size of the installed system as well as the time and money required to maintain the system during the testing process. The system discussed provides a capability to acquire both static (DC) data and dynamic data up to 10,000 Hertz and has a dynamic range in excess of 120 dB.


Files in this item

Thumbnail
Name:
ITC_1988_88-088.pdf
Size:
37.62Kb
Format:
PDF

This item appears in the following Collection(s)

Show simple item record