• Login
    View Item 
    •   Home
    • UA Faculty Research
    • UA Faculty Publications
    • View Item
    •   Home
    • UA Faculty Research
    • UA Faculty Publications
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Browse

    All of UA Campus RepositoryCommunitiesTitleAuthorsIssue DateSubmit DateSubjectsPublisherJournalThis CollectionTitleAuthorsIssue DateSubmit DateSubjectsPublisherJournal

    My Account

    LoginRegister

    About

    AboutUA Faculty PublicationsUA DissertationsUA Master's ThesesUA Honors ThesesUA PressUA YearbooksUA CatalogsUA Libraries

    Statistics

    Most Popular ItemsStatistics by CountryMost Popular Authors

    Computed tomography imaging system design for shape threat detection

    • CSV
    • RefMan
    • EndNote
    • BibTex
    • RefWorks
    Thumbnail
    Name:
    OE_56_4_041308.pdf
    Size:
    2.517Mb
    Format:
    PDF
    Description:
    FInal Published Version
    Download
    Author
    Masoudi, Ahmad
    Thamvichai, Ratchaneekorn
    Neifeld, Mark A.
    Affiliation
    Univ Arizona, Elect & Comp Engn Dept
    Univ Arizona, Coll Opt Sci
    Issue Date
    2016-12-08
    Keywords
    computational imaging
    x-ray
    detection
    computed tomography
    
    Metadata
    Show full item record
    Publisher
    SPIE-SOC PHOTO-OPTICAL INSTRUMENTATION ENGINEERS
    Citation
    Computed tomography imaging system design for shape threat detection 2016, 56 (4):041308 Optical Engineering
    Journal
    Optical Engineering
    Rights
    © 2016 SPIE.
    Collection Information
    This item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at repository@u.library.arizona.edu.
    Abstract
    In the first part of this work, we present two methods for improving the shape-threat detection performance of x-ray computed tomography. Our work uses a fixed-gantry system employing 25 x-ray sources. We first utilize Kullback-Leibler divergence and Mahalanobis distance to determine the optimal single-source single-exposure measurement. The second method employs gradient search on Bhattacharyya bound on error rate (P-e) to determine an optimal multiplexed measurement that simultaneously utilizes all available sources in a single exposure. With limited total resources of 10(6) photons, the multiplexed measurement provides a 41.8x reduction in P-e relative to the single-source measurement. In the second part, we consider multiple exposures and develop an adaptive measurement strategy for x-ray threat detection. Using the adaptive strategy, we design the next measurement based on information retrieved from previous measurements. We determine both optimal "next measurement" and stopping criterion to insure a target P-e using sequential hypothesis testing framework. With adaptive single-source measurements, we can reduce P-e by a factor of 40x relative to the measurements employing all sources in sequence. We also observe that there is a trade-off between measurement SNR and number of detectors when we study the performance of systems with reduced detector numbers. (C) 2016 Society of Photo-Optical Instrumentation Engineers (SPIE)
    ISSN
    0091-3286
    DOI
    10.1117/1.OE.56.4.041308
    Version
    Final published version
    Additional Links
    http://opticalengineering.spiedigitallibrary.org/article.aspx?doi=10.1117/1.OE.56.4.041308
    ae974a485f413a2113503eed53cd6c53
    10.1117/1.OE.56.4.041308
    Scopus Count
    Collections
    UA Faculty Publications

    entitlement

     
    The University of Arizona Libraries | 1510 E. University Blvd. | Tucson, AZ 85721-0055
    Tel 520-621-6442 | repository@u.library.arizona.edu
    DSpace software copyright © 2002-2017  DuraSpace
    Quick Guide | Contact Us | Send Feedback
    Open Repository is a service operated by 
    Atmire NV
     

    Export search results

    The export option will allow you to export the current search results of the entered query to a file. Different formats are available for download. To export the items, click on the button corresponding with the preferred download format.

    By default, clicking on the export buttons will result in a download of the allowed maximum amount of items.

    To select a subset of the search results, click "Selective Export" button and make a selection of the items you want to export. The amount of items that can be exported at once is similarly restricted as the full export.

    After making a selection, click one of the export format buttons. The amount of items that will be exported is indicated in the bubble next to export format.