Assessing computed tomography image quality for combined detection and estimation tasks
Affiliation
Univ Arizona, Coll Opt SciIssue Date
2017-11-21Keywords
computed tomographyiterative reconstruction
channelized scanning linear observer
detection
estimation
estimation receiver operating characteristic
EROC curves
Metadata
Show full item recordCitation
Assessing computed tomography image quality for combined detection and estimation tasks 2017, 4 (04):1 Journal of Medical ImagingJournal
Journal of Medical ImagingRights
© The Authors. Published by SPIE under a Creative Commons Attribution 3.0 Unported License.Collection Information
This item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at repository@u.library.arizona.edu.Abstract
Maintaining or even improving image quality while lowering patient dose is always the desire in clinical computed tomography (CT) imaging. Iterative reconstruction (IR) algorithms have been designed to allow for a reduced dose while maintaining or even improving an image. However, we have previously shown that the dose-saving capabilities allowed with IR are different for different clinical tasks. The channelized scanning linear observer (CSLO) was applied to study clinical tasks that combine detection and estimation when assessing CT image data. The purpose of this work is to illustrate the importance of task complexity when assessing dose savings and to move toward more realistic tasks when performing these types of studies. Human-observer validation of these methods will take place in a future publication. Low-contrast objects embedded in body-size phantoms were imaged multiple times and reconstructed by filtered back projection (FBP) and an IR algorithm. The task was to detect, localize, and estimate the size and contrast of low-contrast objects in the phantom. Independent signal-present and signal-absent regions of interest cropped from images were channelized by the dense-difference of Gauss channels for CSLO training and testing. Estimation receiver operating characteristic (EROC) curves and the areas under EROC curves (EAUC) were calculated by CSLO as the figure of merit. The one-shot method was used to compute the variance of the EAUC values. Results suggest that the IR algorithm studied in this work could efficiently reduce the dose by similar to 50% while maintaining an image quality comparable to conventional FBP reconstruction warranting further investigation using real patient data. (C) The Authors. Published by SPIE under a Creative Commons Attribution 3.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.ISSN
2329-4302PubMed ID
29201940Version
Final published versionSponsors
GE Healthcare, Waukesha, Wisconsinae974a485f413a2113503eed53cd6c53
10.1117/1.JMI.4.4.045503
Scopus Count
Collections
Except where otherwise noted, this item's license is described as © The Authors. Published by SPIE under a Creative Commons Attribution 3.0 Unported License.
Related articles
- Assessing image quality and dose reduction of a new x-ray computed tomography iterative reconstruction algorithm using model observers.
- Authors: Tseng HW, Fan J, Kupinski MA, Sainath P, Hsieh J
- Issue date: 2014 Jul
- Evaluating iterative reconstruction performance in computed tomography.
- Authors: Chen B, Ramirez Giraldo JC, Solomon J, Samei E
- Issue date: 2014 Dec
- Correlation between a 2D channelized Hotelling observer and human observers in a low-contrast detection task with multislice reading in CT.
- Authors: Yu L, Chen B, Kofler JM, Favazza CP, Leng S, Kupinski MA, McCollough CH
- Issue date: 2017 Aug
- Effects of various generations of iterative CT reconstruction algorithms on low-contrast detectability as a function of the effective abdominal diameter: A quantitative task-based phantom study.
- Authors: Viry A, Aberle C, Racine D, Knebel JF, Schindera ST, Schmidt S, Becce F, Verdun FR
- Issue date: 2018 Apr
- Characterization of a commercial hybrid iterative and model-based reconstruction algorithm in radiation oncology.
- Authors: Price RG, Vance S, Cattaneo R 2nd, Schultz L, Elshaikh MA, Chetty IJ, Glide-Hurst CK
- Issue date: 2014 Aug