Experimental limits for eigenvalue calibration in liquid-crystal Mueller-matrix polarimeters
| dc.contributor.author | Bruce, Neil C. | |
| dc.contributor.author | Rodríguez-Herrera, Oscar G. | |
| dc.contributor.author | López-Téllez, Juan Manuel | |
| dc.contributor.author | Rodríguez-Nuñez, Omar | |
| dc.date.accessioned | 2018-07-24T18:24:47Z | |
| dc.date.available | 2018-07-24T18:24:47Z | |
| dc.date.issued | 2018-06-01 | |
| dc.identifier.citation | Neil C. Bruce, Oscar G. Rodríguez-Herrera, Juan Manuel López-Téllez, and Omar Rodríguez-Nuñez, "Experimental limits for eigenvalue calibration in liquid-crystal Mueller-matrix polarimeters," Opt. Lett. 43, 2712-2715 (2018) | en_US |
| dc.identifier.issn | 0146-9592 | |
| dc.identifier.issn | 1539-4794 | |
| dc.identifier.pmid | 29856374 | |
| dc.identifier.doi | 10.1364/OL.43.002712 | |
| dc.identifier.uri | http://hdl.handle.net/10150/628286 | |
| dc.description.abstract | A numerical study is carried out to find the experimental conditions necessary for the eigenvalue calibration procedure to work correctly in a liquid-crystal variableretarder-based Mueller-matrix polarimeter. Using the error between the simulated experimental Mueller matrix in a polarimeter with errors and the expected ideal Mueller matrices for four calibration samples, the maximum experimental errors are estimated for a successful eigenvalue calibration. It is found that the retarder axes' orientations have smaller permitted errors than the retardation values. (C) 2018 Optical Society of America | en_US |
| dc.description.sponsorship | Direccion General de Asuntos del Personal Academico, Universidad Nacional Autonoma de Mexico (DGAPA, UNAM) [PAPIIT IT100114, PAPIIT IT100417] | en_US |
| dc.language.iso | en | en_US |
| dc.publisher | OPTICAL SOC AMER | en_US |
| dc.relation.url | https://www.osapublishing.org/abstract.cfm?URI=ol-43-11-2712 | en_US |
| dc.rights | © 2018 Optical Society of America. | en_US |
| dc.rights.uri | http://rightsstatements.org/vocab/InC/1.0/ | |
| dc.title | Experimental limits for eigenvalue calibration in liquid-crystal Mueller-matrix polarimeters | en_US |
| dc.type | Article | en_US |
| dc.contributor.department | Univ Arizona, Coll Opt Sci | en_US |
| dc.identifier.journal | OPTICS LETTERS | en_US |
| dc.description.note | 12 month embargo; published online: 1 June 2018 | en_US |
| dc.description.collectioninformation | This item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at repository@u.library.arizona.edu. | en_US |
| dc.eprint.version | Final accepted manuscript | en_US |
| dc.source.journaltitle | Optics Letters | |
| dc.source.volume | 43 | |
| dc.source.issue | 11 | |
| dc.source.beginpage | 2712 |
