Direct measurement of radiation pressure and circulating power inside a passive optical cavity
| dc.contributor.author | Wagner, Ryan | |
| dc.contributor.author | Guzman, Felipe | |
| dc.contributor.author | Chijioke, Akobuije | |
| dc.contributor.author | Gulati, Gurpreet Kaur | |
| dc.contributor.author | Keller, Matthias | |
| dc.contributor.author | Shaw, Gordon | |
| dc.date.accessioned | 2019-01-02T16:33:31Z | |
| dc.date.available | 2019-01-02T16:33:31Z | |
| dc.date.issued | 2018-09-03 | |
| dc.identifier.citation | Ryan Wagner, Felipe Guzman, Akobuije Chijioke, Gurpreet Kaur Gulati, Matthias Keller, and Gordon Shaw, "Direct measurement of radiation pressure and circulating power inside a passive optical cavity," Opt. Express 26, 23492-23506 (2018) | en_US |
| dc.identifier.issn | 1094-4087 | |
| dc.identifier.pmid | 30184849 | |
| dc.identifier.doi | 10.1364/OE.26.023492 | |
| dc.identifier.uri | http://hdl.handle.net/10150/631245 | |
| dc.description.abstract | A mechanical force sensor coupled to two optical cavities is developed as a metrological tool. This system is used to generate a calibrated circulating optical power and to create a transfer standard for externally coupled optical power. The variability of the sensor as a transfer standard for optical power is less than 2%. The uncertainty in using the sensor to measure the circulating power inside the cavity is less than 3%. The force measured from the mechanical response of the sensor is compared to the force predicted from characterizing the optical spectrum of the cavity. These two forces are approximately 20% different. Potential sources for this disagreement are analyzed and discussed. The sensor is compact, portable, and can operate in ambient and vacuum environments. This device provides a pathway to novel nanonewton scale force and milliwatt scale laser power calibrations, enables direct measurement of the circulating power inside an optical cavity, and enhances the sensitivity of radiation pressure-based optical power transfer standards. | en_US |
| dc.language.iso | en | en_US |
| dc.publisher | OPTICAL SOC AMER | en_US |
| dc.relation.url | https://www.osapublishing.org/abstract.cfm?URI=oe-26-18-23492 | en_US |
| dc.rights | Journal © 2018. | en_US |
| dc.rights.uri | http://rightsstatements.org/vocab/InC/1.0/ | |
| dc.title | Direct measurement of radiation pressure and circulating power inside a passive optical cavity | en_US |
| dc.type | Article | en_US |
| dc.contributor.department | Univ Arizona, Coll Opt Sci | en_US |
| dc.identifier.journal | OPTICS EXPRESS | en_US |
| dc.description.note | Open access journal. | en_US |
| dc.description.collectioninformation | This item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at repository@u.library.arizona.edu. | en_US |
| dc.eprint.version | Final published version | en_US |
| dc.source.journaltitle | Optics Express | |
| dc.source.volume | 26 | |
| dc.source.issue | 18 | |
| dc.source.beginpage | 23492 | |
| refterms.dateFOA | 2019-01-02T16:33:31Z |
