Advanced treatment of reclaimed water prior to potable reuse normally results in the inactivation of bacterial populations, however, incremental treatment failure can result in bacteria, including pathogens, remaining viable. Therefore, potential microorganisms need to be detected in real-time to preclude potential adverse human health effects. Real-time detection of microbes presents unique problems which are dependent on the water quality of the test water, including parameters such as particulate content and turbidity, and natural organic matter content. In addition, microbes are unusual in that: (i) viability and culturability are not always synonymous; (ii) viability in water can be reduced by osmotic stress; and (iii) bacteria can invoke repair mechanisms in response to UV disinfection resulting in regrowth of bacterial populations. All these issues related to bacteria affect the efficacy of real-time detection for bacteria. Here we evaluate three different sensors suitable for specific water qualities. The sensor A is an on-line, real-time sensor that allows for the continuous monitoring of particulates (including microbial contaminants) using multi-angle-light scattering (MALS) technology. The sensor B is a microbial detection system that uses optical technique, Mie light scattering, for particle sizing and fluorescence emission for viable bacteria detection. The last sensor C was based on adenosine triphosphate (ATP) production. E. coli was used a model organism and out of all tested sensors, we found the sensor C to be the most accurate. It has a great potential as a surrogate parameter for microbial loads in test waters and be useful for process control in treatment trains.Note
Open access journal.ISSN
1424-8220PubMed ID
30012989Version
Final published versionAdditional Links
http://www.mdpi.com/1424-8220/18/7/2303ae974a485f413a2113503eed53cd6c53
10.3390/s18072303
Scopus Count
Collections
Except where otherwise noted, this item's license is described as © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.
Related articles
- Turbidity composition and the relationship with microbial attachment and UV inactivation efficacy.
- Authors: Farrell C, Hassard F, Jefferson B, Leziart T, Nocker A, Jarvis P
- Issue date: 2018 May 15
- Disinfection of water and wastewater by UV-A and UV-C irradiation: application of real-time PCR method.
- Authors: Chatzisymeon E, Droumpali A, Mantzavinos D, Venieri D
- Issue date: 2011 Mar 2
- Growth and repair potential of three species of bacteria in reclaimed wastewater after UV disinfection.
- Authors: Guo M, Huang J, Hu H, Liu W
- Issue date: 2011 Aug
- Photoreactivation of E. coli depending on light intensity after UV irradiation.
- Authors: Schoenen D, Kolch A
- Issue date: 1992 Mar
- [Analysis of Pathogenic Bacteria in Reclaimed Water and Impact of UV Disinfection on the Removal of Pathogenic Bacteria].
- Authors: Jing M, Wang L
- Issue date: 2016 Feb 15