Show simple item record

dc.contributor.authorWenny, Brian N.
dc.contributor.authorThome, Kurtis J.
dc.contributor.authorCzapla-Myers, Jeffrey S.
dc.contributor.authorAnderson, Nikolaus J.
dc.date.accessioned2019-05-15T17:26:35Z
dc.date.available2019-05-15T17:26:35Z
dc.date.issued2017
dc.identifier.citationKurtis Thome, Jeff Czapla-Myers, Brian Wenny, and Nikolaus Anderson "Calibration and use of an ultra-portable field transfer radiometer for automated vicarious calibration", Proc. SPIE 10402, Earth Observing Systems XXII, 104020L (5 September 2017); doi: 10.1117/12.2275498; https://doi.org/10.1117/12.2275498en_US
dc.identifier.issn9781510612617
dc.identifier.issn9781510612624
dc.identifier.doi10.1117/12.2275498
dc.identifier.doi10.1117/12.2275498.5581310019001
dc.identifier.urihttp://hdl.handle.net/10150/632257
dc.description.abstractA small portable transfer radiometer has been developed as part of an effort to ensure the quality of upwelling radiance at automated test sites used for vicarious calibration in the solar reflective. The test sites, such as the one located at Railroad Valley, are used to predict top-of-atmosphere reflectance relying on ground-based measurements of the atmosphere and surface. The portable transfer radiometer is designed for one-person operation for on-site field calibration the instrumentation used to determine ground-leaving radiance. The current work describes the laboratory-based calibration of the transfer radiometer highlighting the expected accuracy and SI-traceability. Results from recent field deployments of the transfer radiometer are presented to show how the sensor is to be used for 1) evaluating the health of the automated site radiometers, 2) characterizing the surface being measured at the automated test sites, and 3) assessing the error budget for top-of-atmosphere reflectance prediction the test site characterization. Additionally, results from using the transfer radiometer for a radiance-based calibration of the Operational Land Imager are presented.en_US
dc.language.isoenen_US
dc.publisherSPIE-INT SOC OPTICAL ENGINEERINGen_US
dc.relation.urlhttps://www.spiedigitallibrary.org/conference-proceedings-of-spie/10402/2275498/Calibration-and-use-of-an-ultra-portable-field-transfer-radiometer/10.1117/12.2275498.fullen_US
dc.relation.urlhttps://www.spiedigitallibrary.org/conference-presentations/10402/104020L/Calibration-and-use-of-an-ultra-portable-field-transfer-radiometer/10.1117/12.2275498.5581310019001en_US
dc.rights© 2017 SPIE.en_US
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/
dc.subjectCLARREOen_US
dc.subjectpreflight calibrationen_US
dc.subjectradiometric calibrationen_US
dc.subjectSI-traceableen_US
dc.titleCalibration and use of an ultra-portable field transfer radiometer for automated vicarious calibrationen_US
dc.typeArticleen_US
dc.contributor.departmentUniv Arizona, Coll Opt Scien_US
dc.identifier.journalEARTH OBSERVING SYSTEMS XXIIen_US
dc.description.collectioninformationThis item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at repository@u.library.arizona.edu.en_US