Influence of the Vibralung Acoustical Percussor on pulmonary function and sputum expectoration in individuals with cystic fibrosis
dc.contributor.author | Wheatley, Courtney M | |
dc.contributor.author | Baker, Sarah E | |
dc.contributor.author | Daines, Cori M | |
dc.contributor.author | Phan, Hanna | |
dc.contributor.author | Martinez, Marina G | |
dc.contributor.author | Morgan, Wayne J | |
dc.contributor.author | Snyder, Eric M | |
dc.date.accessioned | 2019-06-05T23:30:27Z | |
dc.date.available | 2019-06-05T23:30:27Z | |
dc.date.issued | 2018-04-26 | |
dc.identifier.citation | Wheatley, C. M., Baker, S. E., Daines, C. M., Phan, H., Martinez, M. G., Morgan, W. J., & Snyder, E. M. (2018). Influence of the Vibralung Acoustical Percussor on pulmonary function and sputum expectoration in individuals with cystic fibrosis. Therapeutic Advances in Respiratory Disease. https://doi.org/10.1177/1753466618770997 | en_US |
dc.identifier.issn | 1753-4666 | |
dc.identifier.pmid | 29697011 | |
dc.identifier.doi | 10.1177/1753466618770997 | |
dc.identifier.uri | http://hdl.handle.net/10150/632512 | |
dc.description.abstract | Over two separate studies, 10 and 11 mild to moderate CF patients were recruited for study I and II, respectively. Study I: Vibralung was used for 20 min with either no sound (NS: PEP only) or sound (S: PEP and sound) on randomized visits. Pulmonary function, diffusion capacity of the lungs for carbon monoxide and nitric oxide (DLCO/DLNO), symptoms, and peripheral oxygen saturation (SpO2) were measured at baseline and at 1 and 4 h post treatment. Expectorated sputum was collected over 4 h post treatment. Study II: over 5 days of in-hospital therapy, the Vibralung or vibratory vest therapy (Vest) were used for two therapy sessions per day, with sputum collected for 20 min following each therapy and pulmonary function accessed pre and post each 5-day period (days 1-5 or 7-11) in a randomized crossover design. | en_US |
dc.description.sponsorship | WestMed Inc., Tucson, AZ, USA | en_US |
dc.language.iso | en | en_US |
dc.publisher | SAGE PUBLICATIONS LTD | en_US |
dc.relation.url | https://journals.sagepub.com/doi/full/10.1177/1753466618770997 | en_US |
dc.rights | © The Author(s), 2018. This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (http://www.creativecommons.org/licenses/by-nc/4.0/). | en_US |
dc.rights.uri | https://creativecommons.org/licenses/by-nc/4.0/ | |
dc.subject | airway clearance therapy | en_US |
dc.subject | cystic fibrosis | en_US |
dc.subject | diffusing capacity of the lungs for carbon monoxide and nitric oxide | en_US |
dc.subject | high-frequency chest wall oscillation/compression | en_US |
dc.subject | oscillatory positive expiratory pressure | en_US |
dc.subject | pulmonary function | en_US |
dc.subject | sputum expectoration/clearance | en_US |
dc.title | Influence of the Vibralung Acoustical Percussor on pulmonary function and sputum expectoration in individuals with cystic fibrosis | en_US |
dc.type | Article | en_US |
dc.contributor.department | Univ Arizona, Dept Pharm Practice & Sci | en_US |
dc.contributor.department | Univ Arizona, Dept Pharm Practice & Sci | en_US |
dc.contributor.department | Univ Arizona, Dept Pediat Pediat Pulmonol & Sleep | en_US |
dc.contributor.department | Univ Arizona, USA Dept Pediat Pediat Pulmonol & Sleep | en_US |
dc.contributor.department | Univ Arizona, Arizona Clin Res Ctr | en_US |
dc.identifier.journal | THERAPEUTIC ADVANCES IN RESPIRATORY DISEASE | en_US |
dc.description.note | Open access journal | en_US |
dc.description.collectioninformation | This item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at repository@u.library.arizona.edu. | en_US |
dc.eprint.version | Final published version | en_US |
dc.source.journaltitle | Therapeutic advances in respiratory disease | |
refterms.dateFOA | 2019-06-05T23:30:28Z |