Evaluation of dosimetric uncertainty caused by MR geometric distortion in MRI-based liver SBRT treatment planning
Name:
Han_et_al-2019-Journal_of_Appl ...
Size:
909.6Kb
Format:
PDF
Description:
Final Published version
Publisher
WILEYCitation
Han, S. , Yin, F. and Cai, J. (2019), Evaluation of dosimetric uncertainty caused by MR geometric distortion in MRI‐based liver SBRT treatment planning. J Appl Clin Med Phys, 20: 43-50. doi:10.1002/acm2.12520Rights
© 2019 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the Creative Commons Attribution License.Collection Information
This item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at repository@u.library.arizona.edu.Abstract
Purpose MRI-based treatment planning is a promising technique for liver stereotactic-body radiation therapy (SBRT) treatment planning to improve target volume delineation and reduce radiation dose to normal tissues. MR geometric distortion, however, is a source of potential error in MRI-based treatment planning. The aim of this study is to investigate dosimetric uncertainties caused by MRI geometric distortion in MRI-based treatment planning for liver SBRT. Materials and Methods The study was conducted using computer simulations. 3D MR geometric distortion was simulated using measured data in the literature. Planning MR images with distortions were generated by integrating the simulated 3D MR geometric distortion onto planning CT images. MRI-based treatment plans were then generated on the planning MR images with two dose calculation methods: (1) using original CT numbers; and (2) using organ-specific assigned CT numbers. Dosimetric uncertainties of various dose-volume-histogram parameters were determined as their differences between the simulated MRI-based plans and the original clinical CT-based plans for five liver SBRT cases. Results The average simulated distortion for the five liver SBRT cases was 2.77 mm. In the case of using original CT numbers for dose calculation, the average dose uncertainties for target volumes and critical structures were <0.5 Gy, and the average target volume percentage at prescription dose uncertainties was 0.97%. In the case of using assigned CT numbers, the average dose uncertainties for target volumes and critical structures were <1.0 Gy, and the average target volume percentage at prescription dose uncertainties was 2.02%. Conclusions Dosimetric uncertainties caused by MR geometric distortion in MRI-based liver SBRT treatment planning was generally small (<1 Gy) when the distortion is 3 mm.Note
Open access journalISSN
1526-9914PubMed ID
30697915Version
Final published versionSponsors
VarianAdditional Links
https://aapm.onlinelibrary.wiley.com/doi/full/10.1002/acm2.12520ae974a485f413a2113503eed53cd6c53
10.1002/acm2.12520
Scopus Count
Collections
Except where otherwise noted, this item's license is described as © 2019 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the Creative Commons Attribution License.
Related articles
- Dosimetric impact of different CT datasets for stereotactic treatment planning using 3D conformal radiotherapy or volumetric modulated arc therapy.
- Authors: Oechsner M, Odersky L, Berndt J, Combs SE, Wilkens JJ, Duma MN
- Issue date: 2015 Dec 1
- Linac- and CyberKnife-based MRI-only treatment planning of prostate SBRT using an optimized synthetic CT calibration curve.
- Authors: Scholey J, Nano T, Singhrao K, Mohamad O, Singer L, Larson PEZ, Descovich M
- Issue date: 2024 Sep
- Structure guided deformable image registration for treatment planning CT and post stereotactic body radiation therapy (SBRT) Primovist(®) (Gd-EOB-DTPA) enhanced MRI.
- Authors: Kuznetsova S, Grendarova P, Roy S, Sinha R, Thind K, Ploquin N
- Issue date: 2019 Dec
- MRI geometric distortion: Impact on tangential whole-breast IMRT.
- Authors: Walker A, Metcalfe P, Liney G, Batumalai V, Dundas K, Glide-Hurst C, Delaney GP, Boxer M, Yap ML, Dowling J, Rivest-Henault D, Pogson E, Holloway L
- Issue date: 2016 Sep
- Impact of contrast-enhanced CT in the dosimetry of SBRT for liver metastases treated with MR-Linac.
- Authors: Liu M, Liu M, Yang F, Liu Y, Wang S, Chen Y, Li J, Wang X, Orlandini LC
- Issue date: 2024 Oct 15

