Mechanical chest compressions for cardiac arrest in the cath-lab: when is it enough and who should go to extracorporeal cardio pulmonary resuscitation?
Publisher
BMCCitation
Hardig, B. M., Kern, K. B., & Wagner, H. (2019). Mechanical chest compressions for cardiac arrest in the cath-lab: when is it enough and who should go to extracorporeal cardio pulmonary resuscitation?. BMC cardiovascular disorders, 19(1), 134.Journal
BMC CARDIOVASCULAR DISORDERSRights
Copyright © The Author(s). 2019 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/). The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.Collection Information
This item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at repository@u.library.arizona.edu.Abstract
Background Treating patients in cardiac arrest (CA) with mechanical chest compressions (MCC) during percutaneous coronary intervention (PCI) is now routine in many coronary catheterization laboratories (cath-lab) and more aggressive treatment modalities, including extracorporeal CPR are becoming more common. The cath-lab setting enables monitoring of vital physiological parameters and other clinical factors that can potentially guide the resuscitation effort. This retrospective analysis attempts to identify such factors associated with ROSC and survival. Methods In thirty-five patients of which background data, drugs used during the resuscitation and the intervention, PCI result, post ROSC-treatment and physiologic data collected during CPR were compared for prediction of ROSC and survival. Results Eighteen (51%) patients obtained ROSC and 9 (26%) patients survived with good neurological outcome. There was no difference between groups in regards of background data. Patients arriving in the cath-lab with ongoing resuscitation efforts had lower ROSC rate (22% vs 53%; p=0.086) and no survivors (0% vs 50%, p=0.001). CPR time also differentiated resuscitation outcomes (ROSC: 18min vs No ROSC: 50min; p=0.007 and Survivors: 10min vs No Survivors: 45min; p=0.001). Higher arterial diastolic blood pressure was associated with ROSC: 30mmHg vs No ROSC: 19mmHg; p=0.012).Conclusion Aortic diastolic pressure during CPR is the most predictive physiological parameter of resuscitation success. Ongoing CPR upon arrival at the cath-lab and continued MCC beyond 10-20min in the cath-lab were both predictive of poor outcomes. These factors can potentially guide decisions regarding escalation and termination of resuscitation efforts.Note
Open access journalISSN
1471-2261PubMed ID
31159737Version
Final published versionSponsors
LUCAS chest compression system (Stryker/Jolife AB, Lund, Sweden)ae974a485f413a2113503eed53cd6c53
10.1186/s12872-019-1108-1
Scopus Count
Collections
Except where otherwise noted, this item's license is described as Copyright © The Author(s). 2019 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/). The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
Related articles
- Early experiences with miniaturized extracorporeal life-support in the catheterization laboratory.
- Authors: Arlt M, Philipp A, Voelkel S, Schopka S, Husser O, Hengstenberg C, Schmid C, Hilker M
- Issue date: 2012 Nov
- Cardiac Arrest in the Cardiac Catheterization Laboratory: Combining Mechanical Chest Compressions and Percutaneous LV Assistance.
- Authors: Lotun K, Truong HT, Cha KC, Alsakka H, Gianotto-Oliveira R, Smith N, Rao P, Bien T, Chatelain S, Kern MC, Hsu CH, Zuercher M, Kern KB
- Issue date: 2019 Sep 23
- Mechanical chest compressions in the coronary catheterization laboratory to facilitate coronary intervention and survival in patients requiring prolonged resuscitation efforts.
- Authors: Wagner H, Hardig BM, Rundgren M, Zughaft D, Harnek J, Götberg M, Olivecrona GK
- Issue date: 2016 Jan 21
- Mechanical chest compressions improve rate of return of spontaneous circulation and allow for initiation of percutaneous circulatory support during cardiac arrest in the cardiac catheterization laboratory.
- Authors: Venturini JM, Retzer E, Estrada JR, Friant J, Beiser D, Edelson D, Paul J, Blair J, Nathan S, Shah AP
- Issue date: 2017 Jun
- [Influence factors analysis of mechanical compression and hands-only compression on restoration of spontaneous circulation and prognosis in patients with cardiac arrest].
- Authors: Jin K, Fu Y, Yin L, Yu S, Zhang L, Wang Y, Zhu H, Xu J, Yu X
- Issue date: 2019 Mar