Nuclear magnetic resonance biosensor for rapid detection of Vibrio parahaemolyticus
| dc.contributor.author | Hash, Sara | |
| dc.contributor.author | Martinez-Viedma, M Pilar | |
| dc.contributor.author | Fung, Fred | |
| dc.contributor.author | Han, Jee Eun | |
| dc.contributor.author | Yang, Paul | |
| dc.contributor.author | Wong, Charlene | |
| dc.contributor.author | Doraisamy, Loganathan | |
| dc.contributor.author | Menon, Suresh | |
| dc.contributor.author | Lightner, Donald | |
| dc.date.accessioned | 2019-09-26T22:13:50Z | |
| dc.date.available | 2019-09-26T22:13:50Z | |
| dc.date.issued | 2019-07-15 | |
| dc.identifier.citation | Hash, S., Martinez-Viedma, M. P., Fung, F., Han, J. E., Yang, P., Wong, C., ... & Lightner, D. (2019). Nuclear magnetic resonance biosensor for rapid detection of Vibrio parahaemolyticus. biomedical journal, 42(3), 187-192. | en_US |
| dc.identifier.issn | 2319-4170 | |
| dc.identifier.pmid | 31466712 | |
| dc.identifier.doi | 10.1016/j.bj.2019.01.009 | |
| dc.identifier.uri | http://hdl.handle.net/10150/634611 | |
| dc.description.abstract | A Nuclear Magnetic Resonance (NMR)-based detection system was used to detect pathogenic levels of this microorganism (105 CFU/ml) with Molecular Mirroring using iron nanoparticles coated with target-specific biomarkers capable of binding to DNA of the target microorganism. The NMR system generates a signal (in milliseconds) by measuring NMR spin-spin relaxation time T2, which correlates with the amount of microorganism DNA. | en_US |
| dc.language.iso | en | en_US |
| dc.publisher | ELSEVIER | en_US |
| dc.rights | Copyright © 2019 Chang Gung University. Publishing services by Elsevier B.V. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). | en_US |
| dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | |
| dc.subject | Aquaculture | en_US |
| dc.subject | Biosensors | en_US |
| dc.subject | Food safety | en_US |
| dc.subject | Nuclear magnetic resonance (NMR) | en_US |
| dc.subject | Vibrio parahaemolyticus | en_US |
| dc.title | Nuclear magnetic resonance biosensor for rapid detection of Vibrio parahaemolyticus | en_US |
| dc.type | Article | en_US |
| dc.contributor.department | Univ Arizona, Sch Anim & Comparat Biomed Sci | en_US |
| dc.identifier.journal | BIOMEDICAL JOURNAL | en_US |
| dc.description.note | Open access journal | en_US |
| dc.description.collectioninformation | This item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at repository@u.library.arizona.edu. | en_US |
| dc.eprint.version | Final published version | en_US |
| dc.source.journaltitle | Biomedical journal | |
| refterms.dateFOA | 2019-09-26T22:13:51Z |

