Show simple item record

dc.contributor.authorGravbrot, Nicholas
dc.contributor.authorBurket, Aaron
dc.contributor.authorSaranathan, Manojkumar
dc.contributor.authorKasoff, Willard S.
dc.date.accessioned2020-05-19T18:34:35Z
dc.date.available2020-05-19T18:34:35Z
dc.date.issued2020-04-27
dc.identifier.citationGravbrot, N., Burket, A., Saranathan, M. and Kasoff, W.S. (2020), Asleep Deep Brain Stimulation of the Nucleus Ventralis Intermedius for Essential Tremor Using Indirect Targeting and Interventional Magnetic Resonance Imaging: Single‐Institution Case Series. Mov Disord Clin Pract. doi:10.1002/mdc3.12955en_US
dc.identifier.issn2330-1619
dc.identifier.doi10.1002/mdc3.12955
dc.identifier.urihttp://hdl.handle.net/10150/641337
dc.description.abstractBackground Literature on asleep deep brain stimulation (DBS) of the ventralis intermedius (Vim) nucleus in essential tremor is relatively sparse. Furthermore, controversy exists as to whether indirect ("consensus" or "atlas-based") targeting of the Vim requires physiologic adjustment for effective clinical outcomes in DBS surgery. Objectives The objective of this study was to evaluate the clinical results of asleep Vim DBS using indirect coordinates and real-time interventional magnetic resonance imaging guidance. Methods Retrospective review of a prospectively collected database was performed to identify patients with essential tremor undergoing asleep Vim DBS using interventional magnetic resonance imaging guidance. Stereotactic and clinical outcomes were abstracted and analyzed using descriptive statistics. Results A total of 12 consecutive patients were identified, all of whom were available for 6-month clinical follow-up. Stereotactic (radial) error was 0.5 +/- 0.2 mm on the left and 0.5 +/- 0.3 mm on the right. Fahn-Tolosa-Marin tremor scores in the treated limb(s) decreased by 71.2% +/- 31.0% (P = 0.0088), The Essential Tremor Rating Assessment Scale activities of daily living improved by 74.9% +/- 23.7% (P < 0.0001), and The Essential Tremor Rating Assessment Scale performance improved by 64.3 +/- 16.2% (P = 0.0004). Surgical complications were mild and generally transient. Stimulation-related side effects were similar to those reported in historical series of awake Vim DBS. Conclusions Asleep Vim DBS using indirect targeting and interventional magnetic resonance imaging-guided placement is safe and effective, with 6-month clinical results similar to those achieved with awake placement. These data support the use of asleep surgery in essential tremor and represent a baseline for comparison with future studies using more advanced targeting techniques.en_US
dc.language.isoenen_US
dc.publisherWILEYen_US
dc.rights© 2020 International Parkinson and Movement Disorder Society.en_US
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/
dc.subjectasleep DBSen_US
dc.subjectVim thalamusen_US
dc.subjectessential tremoren_US
dc.subjectinterventional MRIen_US
dc.titleAsleep Deep Brain Stimulation of the Nucleus Ventralis Intermedius for Essential Tremor Using Indirect Targeting and Interventional Magnetic Resonance Imaging: Single‐Institution Case Seriesen_US
dc.typeArticleen_US
dc.identifier.eissn2330-1619
dc.contributor.departmentUniv Arizona, Coll Med, Dept Neurosurgen_US
dc.contributor.departmentUniv Arizona, Coll Med, Dept Med Imagingen_US
dc.identifier.journalMOVEMENT DISORDERS CLINICAL PRACTICEen_US
dc.description.note12 month embargo; published online: 14 April 2020en_US
dc.description.collectioninformationThis item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at repository@u.library.arizona.edu.en_US
dc.eprint.versionFinal accepted manuscripten_US
dc.source.journaltitleMovement Disorders Clinical Practice


Files in this item

Thumbnail
Name:
20200315_ET_iMRI manuscript-cl ...
Size:
246.5Kb
Format:
PDF
Description:
Final Accepted Manuscript

This item appears in the following Collection(s)

Show simple item record