dc.identifier.citationTseng, H. W., Karellas, A., & Vedantham, S. (2021). Radiation dosimetry of a clinical prototype dedicated cone‐beam breast CT system with offset detector. Medical Physics.en_US
dc.identifier.issn0094-2405
dc.identifier.doi10.1002/mp.14688
dc.identifier.urihttp://hdl.handle.net/10150/651870
dc.description.abstractPurpose: A clinical-prototype, dedicated, cone-beam breast computed tomography (CBBCT) system with offset detector is undergoing clinical evaluation at our institution. This study is to estimate the normalized glandular dose coefficients ((Formula presented.)) that provide air kerma-to-mean glandular dose conversion factors using Monte Carlo simulations. Materials and methods: The clinical prototype CBBCT system uses 49 kV x-ray spectrum with 1.39 mm 1st half-value layer thickness. Monte Carlo simulations (GATE, version 8) were performed with semi-ellipsoidal, homogeneous breasts of various fibroglandular weight fractions ((Formula presented.), chest wall diameters ((Formula presented.) cm), and chest wall to nipple length ((Formula presented.)), aligned with the axis of rotation (AOR) located at 65 cm from the focal spot to determine the (Formula presented.). Three geometries were considered – (Formula presented.) -cm detector with no offset that served as reference and corresponds to a clinical CBBCT system, (Formula presented.) -cm detector with 5 cm offset, and a (Formula presented.) -cm detector with 10 cm offset. Results: For 5 cm lateral offset, the (Formula presented.) ranged (Formula presented.) mGy/mGy and reduction in (Formula presented.) with respect to reference geometry was observed only for 18 cm ((Formula presented.)) and 20 cm ((Formula presented.)) diameter breasts. For the 10 cm lateral offset, the (Formula presented.) ranged (Formula presented.) mGy/mGy and reduction in (Formula presented.) was observed for all breast diameters. The reduction in (Formula presented.) was (Formula presented.), (Formula presented.), (Formula presented.), (Formula presented.), and (Formula presented.) for 8, 10, 14, 18, and 20 cm diameter breasts, respectively. For a given breast diameter, the reduction in (Formula presented.) with offset-detector geometries was not dependent on (Formula presented.). Numerical fits of (Formula presented.) were generated for each geometry. Conclusion: The (Formula presented.) and the numerical fit, (Formula presented.) would be of benefit for current CBBCT systems using the reference geometry and for future generations using offset-detector geometry. There exists a potential for radiation dose reduction with offset-detector geometry, provided the same technique factors as the reference geometry are used, and the image quality is clinically acceptable. © 2021 American Association of Physicists in Medicineen_US
dc.description.sponsorshipNational Institutes of Healthen_US
dc.language.isoenen_US
dc.publisherJohn Wiley and Sons Ltden_US
dc.rights© 2021 American Association of Physicists in Medicine.en_US
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/en_US
dc.subjectbreast canceren_US
dc.subjectbreast CTen_US
dc.subjectmean glandular doseen_US
dc.subjectMonte Carloen_US
dc.subjectoffset detectoren_US
dc.subjectradiation doseen_US
dc.subjecttruncated detectoren_US
dc.titleRadiation dosimetry of a clinical prototype dedicated cone‐beam breast CT system with offset detectoren_US
dc.typeArticleen_US
dc.identifier.eissn2473-4209
dc.contributor.departmentDepartment of Medical Imaging, The University of Arizonaen_US
dc.contributor.departmentDepartment of Biomedical Engineering, The University of Arizonaen_US
dc.identifier.journalMedical Physicsen_US
dc.description.note12 month embargo; published 26 January 2021en_US
dc.description.collectioninformationThis item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at repository@u.library.arizona.edu.en_US
dc.eprint.versionFinal accepted manuscripten_US
dc.source.journaltitleMedical Physics


Files in this item

Thumbnail
Name:
Truncated_Detector_DgN_Rev1.pdf
Size:
943.0Kb
Format:
PDF
Description:
Final Accepted Manuscript

This item appears in the following Collection(s)

Show simple item record