Cs Feed Tests and Emittance Measurements on a Modified MC-SNICS Ion Source for Radiocarbon AMS
| dc.contributor.author | Southon, John | |
| dc.contributor.author | Santos, Guaciara Dos | |
| dc.contributor.author | Han, Baoxi | |
| dc.date.accessioned | 2021-02-11T20:44:22Z | |
| dc.date.available | 2021-02-11T20:44:22Z | |
| dc.date.issued | 2007-01-01 | |
| dc.identifier.citation | Southon, J., dos Santos, G., & Han, B. (2007). Cs feed tests and emittance measurements on a modified MC-SNICS ion source for radiocarbon AMS. Radiocarbon, 49(2), 301-306. | |
| dc.identifier.issn | 0033-8222 | |
| dc.identifier.doi | 10.1017/S0033822200042223 | |
| dc.identifier.uri | http://hdl.handle.net/10150/653581 | |
| dc.description | From the 19th International Radiocarbon Conference held in Keble College, Oxford, England, April 3-7, 2006. | |
| dc.description.abstract | We report on 2 recent developments in an ongoing program of characterizing and improving the National Electrostatics Corp. (NEC) MC-SNICS ion source at University of California (UC) Irvines Keck AMS laboratory. First, we have investigated the possibility of modifying a large-body (134-sample) MC-SNICS to incorporate the UC Irvine Cs oven and vacuum-insulated Cs feed tube, which provide better confinement of Cs than the standard NEC setup. In our 40-sample source, the feed tube enters the source housing directly below the ionizer assembly. This area cannot be accessed for machining on the 134-sample source, but we have successfully tested a modified geometry where the delivery tube enters the body via the source end flange. Second, we recently installed a second beam profile monitor in the injection line of our spectrometer to allow us to make online emittance measurements. At full output (150 mu-A of C at 55 keV), the emittance of our source at 8 kV sputtering voltage is approximately 40-pi mm mrad. | |
| dc.language.iso | en | |
| dc.publisher | Department of Geosciences, The University of Arizona | |
| dc.relation.url | http://radiocarbon.webhost.uits.arizona.edu/ | |
| dc.rights | Copyright © by the Arizona Board of Regents on behalf of the University of Arizona. All rights reserved. | |
| dc.rights.uri | http://rightsstatements.org/vocab/InC/1.0/ | |
| dc.title | Cs Feed Tests and Emittance Measurements on a Modified MC-SNICS Ion Source for Radiocarbon AMS | |
| dc.type | Proceedings | |
| dc.type | text | |
| dc.identifier.journal | Radiocarbon | |
| dc.description.collectioninformation | The Radiocarbon archives are made available by Radiocarbon and the University of Arizona Libraries. Contact lbry-journals@email.arizona.edu for further information. | |
| dc.eprint.version | Final published version | |
| dc.description.admin-note | Migrated from OJS platform February 2021 | |
| dc.source.volume | 49 | |
| dc.source.issue | 2 | |
| dc.source.beginpage | 301 | |
| dc.source.endpage | 306 | |
| refterms.dateFOA | 2021-02-11T20:44:22Z |