Gas Counting System for 14C Dating of Small Samples in the Kraków Laboratory
| dc.contributor.author | Gorczyca, Zbigniew | |
| dc.contributor.author | Jeleń, Kazimierz | |
| dc.contributor.author | Kuc, Tadeusz | |
| dc.date.accessioned | 2021-02-11T20:44:30Z | |
| dc.date.available | 2021-02-11T20:44:30Z | |
| dc.date.issued | 1998-01-01 | |
| dc.identifier.citation | Gorczyca, Z., Jeleń, K., & Kuc, T. (1998). Gas counting system for 14C dating of small samples in the Kraków laboratory. Radiocarbon, 40(1), 129-135. | |
| dc.identifier.issn | 0033-8222 | |
| dc.identifier.doi | 10.1017/S0033822200017963 | |
| dc.identifier.uri | http://hdl.handle.net/10150/653611 | |
| dc.description | From the 16th International Radiocarbon Conference held in Gronigen, Netherlands, June 16-20, 1997. | |
| dc.description.abstract | The application of traditional gas or liquid scintillation counting (LSC) is necessary for assessing radionuclide activity in countries without operating accelerator mass spectrometry (AMS) facilities. A simple and relatively inexpensive system of mini gas counters for measurement of radiocarbon in archaeological and environmental samples has been set up recently in the Kraków laboratory (Department of Environmental Physics, University of Mining and Metallurgy). The system is composed of a gas purification and counter filling line, three identical 15-mL copper/quartz counters, active and passive shielding, and an electronic unit with data acquisition. One counter measures 22 mg of carbon as CO2 with efficiency >95% at a background reduced to 0.044 cpm by a NaJ(T1) guard counter and lead shield. The detection limit (1 sigma) for a two-week measurement of 48 mL of CO2 is 0.52 pMC. The corresponding counting error of a 100 pMC environmental sample is 1.3 pMC for 22 mgC (one counter) and 0.75 pMC for 66 mgC (three counters filled with the sample). | |
| dc.language.iso | en | |
| dc.publisher | Department of Geosciences, The University of Arizona | |
| dc.relation.url | http://radiocarbon.webhost.uits.arizona.edu/ | |
| dc.rights | Copyright © by the Arizona Board of Regents on behalf of the University of Arizona. All rights reserved. | |
| dc.rights.uri | http://rightsstatements.org/vocab/InC/1.0/ | |
| dc.subject | gaseous phase | |
| dc.subject | copper | |
| dc.subject | Poland | |
| dc.subject | background level | |
| dc.subject | laboratory studies | |
| dc.subject | precision | |
| dc.subject | size | |
| dc.subject | errors | |
| dc.subject | liquid scintillation methods | |
| dc.subject | Central Europe | |
| dc.subject | metals | |
| dc.subject | experimental studies | |
| dc.subject | Europe | |
| dc.subject | charcoal | |
| dc.subject | methods | |
| dc.subject | C 14 | |
| dc.subject | carbon | |
| dc.subject | isotopes | |
| dc.subject | radioactive isotopes | |
| dc.subject | carbon dioxide | |
| dc.subject | absolute age | |
| dc.title | Gas Counting System for 14C Dating of Small Samples in the Kraków Laboratory | |
| dc.type | Proceedings | |
| dc.type | text | |
| dc.identifier.journal | Radiocarbon | |
| dc.description.note | This material was digitized as part of a cooperative project between Radiocarbon and the University of Arizona Libraries. | |
| dc.description.collectioninformation | The Radiocarbon archives are made available by Radiocarbon and the University of Arizona Libraries. Contact lbry-journals@email.arizona.edu for further information. | |
| dc.eprint.version | Final published version | |
| dc.description.admin-note | Migrated from OJS platform February 2021 | |
| dc.source.volume | 40 | |
| dc.source.issue | 1 | |
| dc.source.beginpage | 129 | |
| dc.source.endpage | 135 | |
| refterms.dateFOA | 2021-02-11T20:44:30Z |
