The UA Campus Repository is experiencing systematic automated, high-volume traffic (bots). Temporary mitigation measures to address bot traffic have been put in place; however, this has resulted in restrictions on searching WITHIN collections or using sidebar filters WITHIN collections. You can still Browse by Title/Author/Year WITHIN collections. Also, you can still search at the top level of the repository (use the search box at the top of every page) and apply filters from that search level. Export of search results has also been restricted at this time. Please contact us at any time for assistance - email repository@u.library.arizona.edu.

Show simple item record

dc.contributor.authorOlsson, Ingrid U.
dc.date.accessioned2021-02-11T20:44:59Z
dc.date.available2021-02-11T20:44:59Z
dc.date.issued1998-01-01
dc.identifier.citationOlsson, I. U. (1998). Reduction of the error multiplier by a long-term analysis of the characteristic behaviors of proportional counters. Radiocarbon, 40(1), 143-149.
dc.identifier.issn0033-8222
dc.identifier.doi10.1017/S0033822200017987
dc.identifier.urihttp://hdl.handle.net/10150/653720
dc.descriptionFrom the 16th International Radiocarbon Conference held in Gronigen, Netherlands, June 16-20, 1997.
dc.description.abstractA significant reduction in cosmic-ray activity and backgrounds of the gas-filled proportional counters, as measured in a heavy iron shield, was observed when the Uppsala Conventional 14C laboratory was moved in 1984. The new site was better shielded from cosmic rays because of additional concrete layers above the laboratory. A study that lasted over one year yielded a figure for the muon reduction. The backgrounds were reduced approximately to the extent expected from the soft-component contribution at the old Laboratory as judged from barometric-pressure dependence. After a few years, new electronics enforced, and enabled, the revision and improvement of the standard values for the activity and age calculations. A careful analysis of the results for the counters has increased the accuracy of the small corrections needed to yield internal error-multiplication factors mostly between 1 and 1.5 for the background for short periods of up to 12 months, and <1.1 for the oxalic acid samples combined for the last few years of measurements in the laboratory. Similar results were obtained for two counters.
dc.language.isoen
dc.publisherDepartment of Geosciences, The University of Arizona
dc.relation.urlhttp://radiocarbon.webhost.uits.arizona.edu/
dc.rightsCopyright © by the Arizona Board of Regents on behalf of the University of Arizona. All rights reserved.
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/
dc.subjectheavy metals
dc.subjectanthracite
dc.subjectpressure
dc.subjectiron
dc.subjectcoal
dc.subjectgaseous phase
dc.subjectcarboxylic acids
dc.subjectoxalic acid
dc.subjectbackground level
dc.subjectcosmic rays
dc.subjectstatistical analysis
dc.subjectaccuracy
dc.subjecterrors
dc.subjectorganic acids
dc.subjectmetals
dc.subjectorganic compounds
dc.subjectmethods
dc.subjectC 14
dc.subjectcarbon
dc.subjectisotopes
dc.subjectradioactive isotopes
dc.subjectabsolute age
dc.subjectsedimentary rocks
dc.titleReduction of the Error Multiplier by a Long-Term Analysis of the Characteristic Behaviors of Proportional Counters
dc.typeProceedings
dc.typetext
dc.identifier.journalRadiocarbon
dc.description.noteThis material was digitized as part of a cooperative project between Radiocarbon and the University of Arizona Libraries.
dc.description.collectioninformationThe Radiocarbon archives are made available by Radiocarbon and the University of Arizona Libraries. Contact lbry-journals@email.arizona.edu for further information.
dc.eprint.versionFinal published version
dc.description.admin-noteMigrated from OJS platform February 2021
dc.source.volume40
dc.source.issue1
dc.source.beginpage143
dc.source.endpage149
refterms.dateFOA2021-02-11T20:44:59Z


Files in this item

Thumbnail
Name:
1997-2246-1-PB.pdf
Size:
959.9Kb
Format:
PDF

This item appears in the following Collection(s)

Show simple item record