dc.contributor.authorBronk Ramsey, Christopher
dc.contributor.authorHigham, Thomas
dc.contributor.authorLeach, Philip
dc.date.accessioned2021-02-11T21:46:27Z
dc.date.available2021-02-11T21:46:27Z
dc.date.issued2004-01-01
dc.identifier.citationBronk Ramsey, C., Higham, T., & Leach, P. (2004). Towards high-precision AMS: Progress and limitations. Radiocarbon, 46(1), 17-24.
dc.identifier.issn0033-8222
dc.identifier.doi10.1017/S0033822200039308
dc.identifier.urihttp://hdl.handle.net/10150/654979
dc.descriptionFrom the 18th International Radiocarbon Conference held in Wellington, New Zealand, September 1-5, 2003.
dc.description.abstractPrecision and accuracy in accelerator mass spectrometry (AMS) dating relies on the systematic reduction of errors at all stages of the dating process, from sampling to AMS measurement. With new AMS systems providing much better precision and accuracy for the final stage of the process, we need to review the process as a whole to test the accuracy of reported results. A new High Voltage Engineering Europa (HVEE) AMS system was accepted at Oxford in September 2002. Since then, the system has been in routine use for AMS dating and here we report on our experiences during the first year. The AMS system itself is known to be capable of making measurements on single targets to a precision of better than 0.2% for the 14C/13C ratio and better than 0.1% for the 13C/12C ratio. In routine operation, we measure known-age wood to a precision of just above 0.3%, including uncertainties in background and pretreatment. At these levels, the scatter in results is no higher than reported errors, suggesting that uncertainties of +/25 to +/30 14C yr can be reliably reported on single target measurements. This provides a test of all parts of the process for a particular material in a particular state of preservation. More generally, sample pretreatment should remove as much contamination as feasible from the sample while adding as little laboratory contamination as possible. For more complex materials, such as bone, there is clearly more work needed to prove good reproducibility and insignificant offsets in all circumstances. Strategies for testing accuracy and precision on unknown material are discussed here, as well as the possibilities of one day reaching precisions equivalent to errors of < +/20 14C yr.
dc.language.isoen
dc.publisherDepartment of Geosciences, The University of Arizona
dc.relation.urlhttp://radiocarbon.webhost.uits.arizona.edu/
dc.rightsCopyright © by the Arizona Board of Regents on behalf of the University of Arizona. All rights reserved.
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/
dc.subjectabsolute age
dc.subjectaccelerator mass spectroscopy
dc.subjectaccuracy
dc.subjectbones
dc.subjectC 13 C 12
dc.subjectC 14
dc.subjectC 14 C 13
dc.subjectcarbon
dc.subjectcharcoal
dc.subjecterrors
dc.subjectinstruments
dc.subjectisotope ratios
dc.subjectisotopes
dc.subjectmass spectroscopy
dc.subjectmeasurement
dc.subjectprecision
dc.subjectradioactive isotopes
dc.subjectspectroscopy
dc.subjectstable isotopes
dc.subjectwood
dc.titleTowards High-Precision AMS: Progress and Limitations
dc.typeProceedings
dc.typetext
dc.identifier.journalRadiocarbon
dc.description.collectioninformationThe Radiocarbon archives are made available by Radiocarbon and the University of Arizona Libraries. Contact lbry-journals@email.arizona.edu for further information.
dc.eprint.versionFinal published version
dc.description.admin-noteMigrated from OJS platform February 2021
dc.source.volume46
dc.source.issue1
dc.source.beginpage17
dc.source.endpage24
refterms.dateFOA2021-02-11T21:46:27Z


Files in this item

Thumbnail
Name:
4239-3910-1-PB.pdf
Size:
176.1Kb
Format:
PDF

This item appears in the following Collection(s)

Show simple item record