dc.identifier.citationHusband, Nathaniel Alexander. (2016). DESIGN AND CHARACTERIZATION OF A NASOGASTRIC TUBE PLACEMENT VERIFICATION SYSTEM FOR AT-HOME AND HOSPITAL USE (Bachelor's thesis, University of Arizona, Tucson, USA).
dc.identifier.urihttp://hdl.handle.net/10150/657734
dc.description.abstractNasogastric tubes are hollow thermoplastic tubes used to deliver nutrition to the stomachs of patients who cannot ingest food orally. A common medical malpractice event is the introduction of liquid via these tubes into the respiratory tract instead of the stomach, which can result in fluid aspiration that can lead to patient harm or death. Current standard of practice verifies tube placement in a hospital via a chest X-ray or stomach acid pH test. While these procedures are effective, they are not conducive to repeat verification and require the skills of medical professionals. The goal of the project is to develop a cost-efficient and easy-to-use device that informs the user when the tube has been placed in the stomach, not in the airway. The device is small enough for use within existing tubes and can withstand the corrosive gastric environment for up to 30 days. This design uses an open circuit that is closed by ions present in the acidic fluid of the stomach. The closure of the circuit results in a differential voltage signal that provides the user with a “safe to feed” message.en_US
dc.language.isoenen_US
dc.publisherThe University of Arizona.en_US
dc.rightsCopyright © is held by the author. Digital access to this material is made possible by the University Libraries, University of Arizona. Further transmission, reproduction or presentation (such as public display or performance) of protected items is prohibited except with permission of the author.en_US
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/
dc.titleDESIGN AND CHARACTERIZATION OF A NASOGASTRIC TUBE PLACEMENT VERIFICATION SYSTEM FOR AT-HOME AND HOSPITAL USEen_US
dc.typetexten_US
dc.typeElectronic Thesisen_US
thesis.degree.grantorUniversity of Arizonaen_US
thesis.degree.levelbachelorsen_US
thesis.degree.disciplineHonors Collegeen_US
thesis.degree.disciplineBiomedical Engineeringen_US
thesis.degree.nameB.S.en_US
refterms.dateFOA2021-04-14T23:45:01Z


Files in this item

Thumbnail
Name:
azu_etd_mr_2016_0288_sip1_m.pdf
Size:
11.90Mb
Format:
PDF

This item appears in the following Collection(s)

Show simple item record