Sub-millimeter endoscope demonstrates feasibility of in vivo reflectance imaging, fluorescence imaging, and cell collection in the fallopian tubes
Author
Cordova, R.Kiekens, K.
Burrell, S.
Drake, W.
Kmeid, Z.
Rice, P.
Rocha, A.
Diaz, S.
Yamada, S.
Yozwiak, M.
Nelson, O.L.
Rodriguez, G.C.
Heusinkveld, J.
Shih, I.-M.
Alberts, D.S.
Barton, J.K.
Affiliation
University of Arizona, Department of Biomedical EngineeringUniversity of Arizona, Department of Medicine
Issue Date
2021Keywords
biopsyendoscope
fallopian tubes
fluorescence
ovarian cancer
serous tubal intraepithelial carcinoma
Metadata
Show full item recordCitation
Cordova, R., Kiekens, K., Burrell, S., Drake, W., Kmeid, Z., Rice, P., Rocha, A., Diaz, S., Yamada, S., Yozwiak, M., Nelson, O. L., Rodriguez, G. C., Heusinkveld, J., Shih, I.-M., Alberts, D. S., & Barton, J. K. (2021). Sub-millimeter endoscope demonstrates feasibility of in vivo reflectance imaging, fluorescence imaging, and cell collection in the fallopian tubes. Journal of Biomedical Optics, 26(7).Journal
JOURNAL OF BIOMEDICAL OPTICSRights
Copyright © The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License.Collection Information
This item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at repository@u.library.arizona.edu.Abstract
SIGNIFICANCE: Most cases of high-grade serous ovarian carcinoma originate as serous tubal intraepithelial carcinoma (STIC) lesions in the fallopian tube epithelium (FTE), enabling early endoscopic detection. AIM: The cell-acquiring fallopian endoscope (CAFE) was built to meet requirements for locating potentially pathological tissue indicated by an alteration in autofluorescence or presence of a targeted fluorophore. A channel was included for directed scrape biopsy of cells from regions of interest. APPROACH: Imaging resolution and fluorescence sensitivity were measured using a standard resolution target and fluorescence standards, respectively. A prototype was tested in ex vivo tissue, and collected cells were counted and processed. RESULTS: Measured imaging resolution was 88 μm at a 5-mm distance, and full field of view was ∼45 deg in air. Reflectance and fluorescence images in ex vivo porcine reproductive tracts were captured, and fit through human tracts was verified. Hemocytometry counts showed that on the order of 105 cells per scrape biopsy could be collected from ex vivo porcine tissue. CONCLUSIONS: All requirements for viewing STIC in the FTE were met, and collected cell counts exceeded input requirements for relevant analyses. Our benchtop findings suggest the potential utility of the CAFE device for in vivo imaging and cell collection in future clinical trials.Note
Open access articleISSN
1560-2281PubMed ID
34216135Version
Final published versionae974a485f413a2113503eed53cd6c53
10.1117/1.JBO.26.7.076001
Scopus Count
Collections
Except where otherwise noted, this item's license is described as Copyright © The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License.