Show simple item record

dc.contributor.authorBaur, D.
dc.contributor.authorSchwabl, C.
dc.contributor.authorKremser, C.
dc.contributor.authorTaljanovic, M.S.
dc.contributor.authorWidmann, G.
dc.contributor.authorSconfienza, L.M.
dc.contributor.authorSztankay, J.
dc.contributor.authorFeuchtner, G.
dc.contributor.authorKlauser, A.S.
dc.date.accessioned2021-09-24T21:00:43Z
dc.date.available2021-09-24T21:00:43Z
dc.date.issued2021
dc.identifier.citationBaur, D., Schwabl, C., Kremser, C., Taljanovic, M. S., Widmann, G., Sconfienza, L. M., Sztankay, J., Feuchtner, G., & Klauser, A. S. (2021). Shear wave elastography of the plantar fascia: Comparison between patients with plantar fasciitis and healthy control subjects. Journal of Clinical Medicine, 10(11).
dc.identifier.issn2077-0383
dc.identifier.doi10.3390/jcm10112351
dc.identifier.urihttp://hdl.handle.net/10150/661925
dc.description.abstractBackground: The purpose of this study was to evaluate plantar fasciae of healthy subjects and patients with plantar fasciitis by shear wave velocity (SWV) and stiffness with correlation to B-Mode and color Doppler ultrasonography (CDUS) and to establish cut-off values. Methods: This observational study was conducted with the approval of the Institutional Review Boards (IRBs) of our institution. 108 unilateral plantar fasciae were evaluated by including 87 consecutive patients (mean age 51.7; range: 29–82) (66 women and 21 men) with plantar fasciitis and 21 asymptomatic age matched healthy volunteers (mean age 47.3; range: 32–58) (15 women and 6 men). All patients were prospectively imaged between July 2018 and March 2019. B-mode US was used to measure thickness and CDUS to grade vascularity. SWE measurements were repeated 3 times and mean was used for statistical analysis. Results: Mean SWV value in healthy subjects was 6.94 m/s and in patients 4.98 m/s with a mean stiffness value of 152.88 kPa and 93.54 kPa respectively (p < 0.001). For SWV a cut-off value of 6.16 m/s had a specificity of 80.95% and sensitivity of 79.31%. For stiffness a cut-off value of 125.57 kPa had a specificity of 80.95% and sensitivity of 80.46%. No correlation to CDUS was found. The mean thickness of healthy fascias was 3.3 mm (range 2.4–3.9) compared to 6.1 mm (range 2.0–22.0) in plantar fasciitis (p < 0.001) with no correlation to SWV or to stiffness (r2 = 0.02, p = 0.06). Conclusion: SWE allows quantitative assessment of plantar fascia stiffness, which decreases in patients with plantar fasciitis. No correlation to the thickness of the plantar fascia was found, therefore it represents an independent factor for the diagnosis of plantar fasciitis and could be helpful in addition to thickness measurement in unclear cases. © 2021 by the authors. Licensee MDPI, Basel, Switzerland.
dc.language.isoen
dc.publisherMDPI
dc.rightsCopyright © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectColor doppler ultrasonography
dc.subjectElastography
dc.subjectPlantar fascia
dc.subjectPlantar fasciitis
dc.subjectShear wave
dc.titleShear wave elastography of the plantar fascia: Comparison between patients with plantar fasciitis and healthy control subjects
dc.typeArticle
dc.typetext
dc.contributor.departmentBanner University Medical Center, Department of Medical Imaging, College of Medicine, The University of Arizona
dc.identifier.journalJournal of Clinical Medicine
dc.description.noteOpen access journal
dc.description.collectioninformationThis item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at repository@u.library.arizona.edu.
dc.eprint.versionFinal published version
dc.source.journaltitleJournal of Clinical Medicine
refterms.dateFOA2021-09-24T21:00:43Z


Files in this item

Thumbnail
Name:
jcm-10-02351.pdf
Size:
2.701Mb
Format:
PDF
Description:
Final Published Version

This item appears in the following Collection(s)

Show simple item record

Copyright © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Except where otherwise noted, this item's license is described as Copyright © 2021 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).