Remote measurement of sphero-cylindrical lens power and orientation through distortion analysis
dc.contributor.author | Schwiegerling, J. | |
dc.contributor.author | Guan, Y. | |
dc.contributor.author | Miller, J.M. | |
dc.contributor.author | Harvey, E.M. | |
dc.date.accessioned | 2021-11-29T20:24:44Z | |
dc.date.available | 2021-11-29T20:24:44Z | |
dc.date.issued | 2021 | |
dc.identifier.citation | Schwiegerling, J., Guan, Y., Miller, J. M., & Harvey, E. M. (2021). Remote measurement of sphero-cylindrical lens power and orientation through distortion analysis. Proceedings of SPIE - The International Society for Optical Engineering. | |
dc.identifier.isbn | 9781510644687 | |
dc.identifier.issn | 0277-786X | |
dc.identifier.doi | 10.1117/12.2594953 | |
dc.identifier.uri | http://hdl.handle.net/10150/662384 | |
dc.description.abstract | A system for measuring the orientation and power of sphero-cylindrical lenses has been developed. The system attempts to minimize the need for specialized equipment and training and instead relies on the ubiquitous cell phone camera, a magnetic stripe card, and a target pattern. By capturing an image of the target through the lenses under test and analyzing the distortion in the resulting image, the orientation and powers on sphero-cylindrical lenses can be determined. In modern eye clinics, the measurement of sphero-cylindrical spectacle lenses is readily measured with a lensmeter. However, there are many examples where this measurement is not feasible. This may include remote or rural locations where access to eye care may not exist, or require impractical travel. Furthermore, the on-going global pandemic has often put restrictions on contact between the patient and the eye care provider. Telemedicine, which can connect patients to eye care providers, lacks physical access to the spectacles for measurement. The system developed in this effort overcomes this limitation by allowing remote measurement of the lenses with items found in most households. Such a system would be beneficial to often underserved populations and expand access to quality eye care. © COPYRIGHT SPIE. Downloading of the abstract is permitted for personal use only. | |
dc.language.iso | en | |
dc.publisher | SPIE | |
dc.rights | Copyright © 2021 SPIE. | |
dc.rights.uri | http://rightsstatements.org/vocab/InC/1.0/ | |
dc.subject | Image processing | |
dc.subject | Power measurement | |
dc.subject | Spectacle lenses | |
dc.subject | Telemedicine | |
dc.title | Remote measurement of sphero-cylindrical lens power and orientation through distortion analysis | |
dc.type | Proceedings | |
dc.type | text | |
dc.contributor.department | James C. Wyant College of Optical Sciences, University of Arizona | |
dc.contributor.department | Dept. of Ophthalmology and Vision Sciences | |
dc.identifier.journal | Proceedings of SPIE - The International Society for Optical Engineering | |
dc.description.note | Immediate access | |
dc.description.collectioninformation | This item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at repository@u.library.arizona.edu. | |
dc.eprint.version | Final published version | |
dc.source.journaltitle | Proceedings of SPIE - The International Society for Optical Engineering | |
refterms.dateFOA | 2021-11-29T20:24:44Z |