Usability and performance validation of an ultra-lightweight and versatile untethered robotic ankle exoskeleton
Name:
s12984-021-00954-9.pdf
Size:
4.631Mb
Format:
PDF
Description:
Final Published Version
Affiliation
College of Medicine – Phoenix, University of ArizonaIssue Date
2021Keywords
AnkleCerebral palsy
Dorsiflexor assistance
Exoskeleton
Incline walking
Metabolic power
Plantarflexor assistance
Stair ascent
Metadata
Show full item recordPublisher
BioMed Central LtdCitation
Orekhov, G., Fang, Y., Cuddeback, C. F., & Lerner, Z. F. (2021). Usability and performance validation of an ultra-lightweight and versatile untethered robotic ankle exoskeleton. Journal of NeuroEngineering and Rehabilitation.Rights
Copyright © The Author(s) 2021. This article is licensed under a Creative Commons Attribution 4.0 International License.Collection Information
This item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at repository@u.library.arizona.edu.Abstract
Background: Ankle exoskeletons can improve walking mechanics and energetics, but few untethered devices have demonstrated improved performance and usability across a wide range of users and terrains. Our goal was to design and validate a lightweight untethered ankle exoskeleton that was effective across moderate-to-high intensity ambulation in children through adults with and without walking impairment. Methods: Following benchtop validation of custom hardware, we assessed the group-level improvements in walking economy while wearing the device in a diverse unimpaired cohort (n = 6, body mass = 42–92 kg). We also conducted a maximal exertion experiment on a stair stepping machine in a small cohort of individuals with cerebral palsy (CP, n = 5, age = 11–33 years, GMFCS I-III, body mass = 40–71 kg). Device usability metrics (device don and setup times and System Usability Score) were assessed in both cohorts. Results: There was a 9.9 ± 2.6% (p = 0.012, range = 0–18%) reduction in metabolic power during exoskeleton-assisted inclined walking compared to no device in the unimpaired cohort. The cohort with CP was able to ascend 38.4 ± 23.6% (p = 0.013, range = 3–132%) more floors compared to no device without increasing metabolic power (p = 0.49) or perceived exertion (p = 0.50). Users with CP had mean device don and setup times of 3.5 ± 0.7 min and 28 ± 6 s, respectively. Unimpaired users had a mean don time of 1.5 ± 0.2 min and setup time of 14 ± 1 s. The average exoskeleton score on the System Usability Scale was 81.8 ± 8.4 (“excellent”). Conclusions: Our battery-powered ankle exoskeleton was easy to use for our participants, with initial evidence supporting effectiveness across different terrains for unimpaired adults, and children and adults with CP. Trial registration Prospectively registered at ClinicalTrials.gov (NCT04119063) on October 8, 2019. © 2021, The Author(s).Note
Open access journalISSN
1743-0003Version
Final published versionae974a485f413a2113503eed53cd6c53
10.1186/s12984-021-00954-9
Scopus Count
Collections
Except where otherwise noted, this item's license is described as Copyright © The Author(s) 2021. This article is licensed under a Creative Commons Attribution 4.0 International License.