Show simple item record

dc.contributor.authorRuiz-Gonzalez, M.
dc.contributor.authorRichards, R.G.
dc.contributor.authorDoty, K.J.
dc.contributor.authorKuo, P.H.
dc.contributor.authorKupinski, M.A.
dc.contributor.authorFurenlid, L.R.
dc.contributor.authorKing, M.A.
dc.date.accessioned2022-07-06T23:57:21Z
dc.date.available2022-07-06T23:57:21Z
dc.date.issued2022
dc.identifier.citationRuiz-Gonzalez, M., Richards, R. G., Doty, K. J., Kuo, P. H., Kupinski, M. A., Furenlid, L. R., & King, M. A. (2022). A read-out strategy for high-resolution large-area SiPM-based modular gamma-ray cameras. Progress in Biomedical Optics and Imaging - Proceedings of SPIE, 12031.
dc.identifier.isbn9781510649378
dc.identifier.issn1605-7422
dc.identifier.doi10.1117/12.2610069
dc.identifier.urihttp://hdl.handle.net/10150/665301
dc.description.abstractOngoing developments in the field of molecular imaging have increased the need for gamma-ray detectors with better spatial resolution, while maintaining a large detection area. One approach to improve spatial resolution is to utilize smaller light sensors for finer sampling of scintillation light distribution. However, the number of required sensors per camera must increase significantly, which in turn increases the complexity of the imaging system. Examples of challenges that arise are the analog-to-digital conversion of large numbers of channels, and a bottleneck effect that results from transferring large amounts of raw list-mode data to an acquisition computer. Here we present the design of a read-out electronics system that addresses these challenges. The read-out system, which is designed for a 10"× 10"SiPM-based scintillation gamma-ray camera, can process up to 162 light-sensor signals per event. This is achieved by implementing 1-bit and non-uniform 2-bit sigma-delta modulation analogto-digital conversion, and an on-board processing system with a large number of input/output user pins and relatively high processing power. The processor is a system-on-a-module that also has SDRAM, which allows us to buffer raw list-mode data on board. The bottleneck effect is avoided by buffering event data on the camera module, and only transferring it when the main acquisition computer requests it. This design can be adapted for other crystal/sensor configurations, and can be scaled for a different number of channels. © 2022 SPIE.
dc.language.isoen
dc.publisherSPIE
dc.rightsCopyright © 2022 SPIE.
dc.rights.urihttp://rightsstatements.org/vocab/InC/1.0/
dc.subjectGamma-ray imaging
dc.subjectread-out electronics
dc.subjectscintillation camera
dc.subjectSiPM
dc.subjectSPECT
dc.titleA read-out strategy for high-resolution large-area SiPM-based modular gamma-ray cameras
dc.typeProceedings
dc.typetext
dc.contributor.departmentDepartment of Medical Imaging, University of Arizona
dc.contributor.departmentCollege of Optical Sciences, University of Arizona
dc.identifier.journalProgress in Biomedical Optics and Imaging - Proceedings of SPIE
dc.description.noteImmediate access
dc.description.collectioninformationThis item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at repository@u.library.arizona.edu.
dc.eprint.versionFinal published version
dc.source.journaltitleProgress in Biomedical Optics and Imaging - Proceedings of SPIE
refterms.dateFOA2022-07-06T23:57:21Z


Files in this item

Thumbnail
Name:
120314K.pdf
Size:
1.388Mb
Format:
PDF
Description:
Final Published Version

This item appears in the following Collection(s)

Show simple item record