• Login
    View Item 
    •   Home
    • UA Graduate and Undergraduate Research
    • UA Theses and Dissertations
    • Master's Theses
    • View Item
    •   Home
    • UA Graduate and Undergraduate Research
    • UA Theses and Dissertations
    • Master's Theses
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Browse

    All of UA Campus RepositoryCommunitiesTitleAuthorsIssue DateSubmit DateSubjectsPublisherJournalThis CollectionTitleAuthorsIssue DateSubmit DateSubjectsPublisherJournal

    My Account

    LoginRegister

    About

    AboutUA Faculty PublicationsUA DissertationsUA Master's ThesesUA Honors ThesesUA PressUA YearbooksUA CatalogsUA Libraries

    Statistics

    Most Popular ItemsStatistics by CountryMost Popular Authors

    Noninvasive Acoustoelectric Imaging of Spatiotemporally Varying Currents to Diagnose Neuronal Electrical Dysfunction

    • CSV
    • RefMan
    • EndNote
    • BibTex
    • RefWorks
    Thumbnail
    Name:
    azu_etd_20166_sip1_m.pdf
    Size:
    1.900Mb
    Format:
    PDF
    Download
    Author
    Trujillo, Teodoro Esteven
    Issue Date
    2023
    Keywords
    Biomedical Technology
    Epilepsy
    Functional Brain Imaging
    Neurophysiology
    Transcranial Acoustoelectrical Brain Imaging
    Travelling waves
    Advisor
    Witte, Russell S.
    
    Metadata
    Show full item record
    Publisher
    The University of Arizona.
    Rights
    Copyright © is held by the author. Digital access to this material is made possible by the University Libraries, University of Arizona. Further transmission, reproduction, presentation (such as public display or performance) of protected items is prohibited except with permission of the author.
    Abstract
    Transcranial Acoustoelectric Brain Imaging (tABI) offers what Scalp Electroencephalography (EEG) alone fails to offer in the complete characterization of epilepsy. Invasive Depth Electrode (DE) EEG techniques may achieve localized detection of neuronal function and noninvasive scalp EEG sacrifices accuracy of signal detection for safety. The goal of this work was defined through noninvasively visualizing travelling current densities of the brain at varying locations and times, determining signal detection limits and calculating conduction velocities of travelling deep neuronal waves. I proposed a method to detect signal profiles that changed over a period of 50 ms and 35mm distance. Neural currents were simulated ex-vivo in a human head model using a 12-site Spencer/AdTech Depth Electrode (DE) and Infinity Deep Brain Stimulator (DBS) with varying current geometries (dipole, monopole). Slow ≤ 200 Hz and varying magnitude signals were used to emulate neuronal signals in an agarose/saline gel brain phantom inside a real human skull. TABI movies were produced using a 0.6 MHz center frequency, 2D Ultrasound (US) array. These movies provide demonstrable evidence of effective correction for transcranial US imaging of specific current locations with millimeter (mm) and millisecond (ms) accuracy, more specifically, track these signals as they travel spatially and temporally regardless of their direction of travel. Conduction velocities were found through tracking centroid peak magnitude coordinates (x,y,z) over time to map more effectively specific (1.5mm and 4.5mm site separation on Infinity and AdTech electrodes, respectively) spanning wide field of view (35mm) at sub-cranial depth of ~30mm. Current detection limits were nominally found to be ≤300µA. Site to site conduction velocities were determined to be 4.71 m/s and 3.9 m/s on the AdTech and Infinity electrodes, respectively. TABI offers a safe, noninvasive, accurate and less expensive route to better track epileptic (ictal) signals, neural degenerative disease, and cardiac fibrillation in the human brain and heart model. In the final chapter of this work, a prototypical cardiac arrhythmia ex-vivo model is described. Baseline tests were made and there remains room for improvement with design ideas listed for better emulation of the heart electrical dysfunction included.
    Type
    text
    Electronic Thesis
    Degree Name
    M.E.
    Degree Level
    masters
    Degree Program
    Graduate College
    Biomedical Engineering
    Degree Grantor
    University of Arizona
    Collections
    Master's Theses

    entitlement

     
    The University of Arizona Libraries | 1510 E. University Blvd. | Tucson, AZ 85721-0055
    Tel 520-621-6442 | repository@u.library.arizona.edu
    DSpace software copyright © 2002-2017  DuraSpace
    Quick Guide | Contact Us | Send Feedback
    Open Repository is a service operated by 
    Atmire NV
     

    Export search results

    The export option will allow you to export the current search results of the entered query to a file. Different formats are available for download. To export the items, click on the button corresponding with the preferred download format.

    By default, clicking on the export buttons will result in a download of the allowed maximum amount of items.

    To select a subset of the search results, click "Selective Export" button and make a selection of the items you want to export. The amount of items that can be exported at once is similarly restricted as the full export.

    After making a selection, click one of the export format buttons. The amount of items that will be exported is indicated in the bubble next to export format.