Automated Data Check and Calibration System using Matrix Switch Prototype With Small Change of Line-Resistance
Author
Lee, NahyeokKim, Jieun
Lim, Chaemin
Kim, Seongjong
Kim, Youngsik
Lee, Woonmoon
Yoon, Wonju
Noh, Seongmin
Affiliation
Danam SystemsKorea Aerospace Research Institute
Issue Date
2023-10
Metadata
Show full item recordCitation
Lee, N., Kim, J., Lim, C., Kim, S., Kim, Y., Lee, W., Yoon, W., & Noh, S. (2023). Automated Data Check and Calibration System using Matrix Switch Prototype With Small Change of Line-Resistance. International Telemetering Conference Proceedings, 58.Additional Links
https://telemetry.org/Abstract
In this paper, the hardware performance of a matrix switch prototype with small resistance deviation of each route and an automated data check and calibration system are described. The matrix consists of 12 rows and 3 columns, and the key switch connecting the rows and columns has a small on-resistance change even when the input voltage changes, so the matrix can keep the resistance deviation of each route small. Data check and calibration of circuits that are sensitive to errors due to lead-wires can also be automated with this matrix system to save time and reduce human error.Type
Proceedingstext
Language
enISSN
1546-21880884-5123
0074-9079