Accuracy of an objective binocular automated phoropter for providing spectacle prescriptions
Name:
CEOptom-23-254-OP.R1_Proof_hi.pdf
Size:
875.9Kb
Format:
PDF
Description:
Final Accepted Manuscript
Author
Ozgur, ErolBlanche, Pierre-Alexandre
Bedrick, Edward J
Conway, Mandi D
Peyman, Gholam A
Peyghambarian, Nasser N
Affiliation
Wyant College of Optical Sciences, University of ArizonaDepartment of Epidemiology and Biostatistics, University of Arizona
College of Medicine Phoenix, University of Arizona, Phoenix
Issue Date
2023-10-16
Metadata
Show full item recordPublisher
Informa UK LimitedCitation
Erol Ozgur, Pierre-Alexandre Blanche, Edward J Bedrick, Mandi D Conway, Gholam A Peyman & Nasser N Peyghambarian (2023) Accuracy of an objective binocular automated phoropter for providing spectacle prescriptions, Clinical and Experimental Optometry, DOI: 10.1080/08164622.2023.2266498Rights
© 2023 Optometry Australia.Collection Information
This item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at repository@u.library.arizona.edu.Abstract
Clinical relevance: Currently eye examinations are usually based on autorefraction followed by subjective refraction (SR) with a phoropter. An automated phoropter that can also perform autorefraction may facilitate the optometric workflow. Background: The efficiency and feasibility of an objective autorefraction and correction system are assessed by comparing objective refractive measurements with SR on the same subjects and evaluating the visual acuity (VA) values obtained after the objective refractive measurement and correction. Methods: Objective autorefraction and correction was performed on 41 subjects using an automated binocular phoropter system. The auto-phoropter performs autorefraction by wavefront measurement and corrects the spherical and cylindrical errors with tunable fluidic lenses while the patient looks at a visual display inside the instrument. The instrument outputs are optometric constants of spherical and cylindrical aberrations. After measurement and automated correction of the refractive errors, the VA values were assessed by having the subjects look at an integrated Snellen chart. The objective measurement results were statistically compared with their SR. Results: The correlations between SR and objective autorefraction and correction spherical equivalents (M) were 0.98 (0.97–0.99) and 0.96 (0.93–0.98), the vertical Jackson cross cylinder (J0) were 0.96 (0.92–0.98) and 0.95 (0.91–0.97), and the oblique Jackson cross cylinder (J45) were 0.73 (0.55–0.85) and 0.82 (0.69–0.90), for the right and left eyes, respectively, with the 95% confidence interval (CI) values in parentheses. 89.0% of the 82 eyes had at least 6/7.5 VA. Conclusions: A significant agreement between the SR and objective autorefraction and correction was observed. An all-objective refractive assessment with instantaneous verification may improve the precision of eye prescriptions and possibly reduce the procedure time.Note
12 month embargo; first published 16 October 2023ISSN
0816-4622EISSN
1444-0938Version
Final accepted manuscriptae974a485f413a2113503eed53cd6c53
10.1080/08164622.2023.2266498