Shape-adjustable heliostats – designs for individuals and fields for > 3000 concentration
Affiliation
Department of Astronomy, Steward Observatory, University of ArizonaIssue Date
2023-10-04
Metadata
Show full item recordPublisher
SPIECitation
N. Didato, R. Angel, M. Rademacher, "Shape-adjustable heliostats: designs for individuals and fields for > 3000 concentration," Proc. SPIE 12671, Advances in Solar Energy: Heliostat Systems Design, Implementation, and Operation, 126710D (4 October 2023); https://doi.org/10.1117/12.2681483Rights
© 2023 SPIE.Collection Information
This item from the UA Faculty Publications collection is made available by the University of Arizona with support from the University of Arizona Libraries. If you have questions, please contact us at repository@u.library.arizona.edu.Abstract
Shape-adjustable heliostats can maintain a focused image of the solar disc on a receiver target throughout the day, as the angle of incidence (AOI) changes on the reflector. This requires the heliostat reflector to be deformed into a unique biconic concave shape dependent on AOI. The reflector comprises a single rectangular sheet of silvered float glass mounted to a steel frame. Its shape is set initially, by adjusting the height of mounting points, to the biconic shape required for imaging at 60 degrees AOI. Shapes for other AOIs are obtained by twisting the frame from its four corners and center. A finite element model was made of a heliostat designed to form a disc image on a 130 m distant receiver using a single sheet glass reflector, 1/8” thick x 130” x 96”, supported by 58 points on a rectangular tube frame structure weighing 120 kg. Analysis shows an overall RMS slope error <1 mrad for all AOI from 0 to 70 degrees. Without twisting, the RMS slope error would be ~3.5 mrad at 0° and 70° AOI. Preliminary results from analysis of slope error maps generated from the FE model indicate encircled energies within the ideal solar disc radius of >85% are achievable. Models of fields of closely packed heliostats of this type, on target axis mounts, demonstrate a geometrical throughput into the receiver of >73% of the total mirror area, after accounting for blocking, shadowing, and cosine loss. In one model, with 450 heliostats powering five compound parabolic concentrators at a receiver, a concentration of > 3,000 was obtained at powers > 1 MW, through much of the day. © 2023 SPIE.Note
Immediate accessISSN
0277-786XISBN
978-151066556-9Version
Final Published Versionae974a485f413a2113503eed53cd6c53
10.1117/12.2681483